摘要
对原子荧光光度计检测水中汞进行了研究,发现使用5%的盐酸做载流液,10 g/L的硼氢化钾溶液做还原剂等检测条件下,其实验结果令人满意。
The determination of mercury in water with atomic fluorescence spectrometer has been studied. The experimental results are satisfactory when the determination conditions are:5% hydrochloric acid is used as carrier liquid and 10 g/L potassium borohydride is used as reductant, etc.
出处
《工业水处理》
CAS
CSCD
北大核心
2010年第5期72-74,共3页
Industrial Water Treatment
关键词
原子荧光光度计
汞
检测条件
atomic fluorescence spectrometer
mercury
determination conditions