摘要
空调系统在夏季运行时,当冷却器的表面温度低于空气的露点温度时,空气经过冷却器时就会析出冷凝水,通过空调冷凝水水量、水温及水质测试分析,将空调冷凝水再利用到空调冷却水系统,不仅提高制冷装置的制冷系数,而且节约水资源。
The condensed water can be separated out from the air through the condenser, if the surface temperature of the condenser is lower than the dew point temperature of the air when the conditioning system operates in summer. Through testing and analyzing the quantity, temperature and quality of air-conditioning condensed water, it would be possible to recycle the condensed water into the condensation system, which will not only improve the refrigeration coefficient in condensation device but also save the water recourse.
出处
《建筑节能》
CAS
2010年第5期75-77,共3页
BUILDING ENERGY EFFICIENCY
关键词
空调冷凝水
节水分析
节能分析
再利用
airconditioning condensed water
analysis on water-saving
analysis on energy-saving
recycling