摘要 在分析电火工品静电作用机理的基础上,利用瞬态脉冲试验原理研究了静电放电对电火工品的性能影响。分析了因电火工品个体差异导致分组不均给试验带来的影响,提出用瞬态脉冲试验得到的温升参数对样品进行分组,以保证试验样品的一致性。研究结果表明,经过静电放电试验后,电火工品温升值变大,平均作用时间变长。说明可以用瞬态脉冲试验法检测经静电放电后电火工品的性能变化。 Based on analyzing the mechanism of electric explosive devises (EEDs) stimulated by ESD, this paper investigates the performance influence of ESD stimulus on EEDs with the principle of transient pulse test (TPT). Different EEDs can bring about ununiform groups and this paper analyzes it influences on the experiment, putting forward the method of classifying the sample according to the tempermture rise, to safeguard the uniformity of the experimental samples, The investigation result shows that after ESD stimulus, the temperature rise of EEDs is higher and the function time of EEDs is longer, so transient pulse test can be used to check the performance variation of EEDs after ESD stimulus.
出处 《工业安全与环保》 北大核心 2010年第5期39-40,共2页 Industrial Safety and Environmental Protection
关键词 瞬态脉冲试验 静电放电 电火工品 transient pulse test KSD electric explosive devices
  • 相关文献

参考文献3

二级参考文献4

  • 1Munger A C. Electrothermal response testing more than a quality assurance tool[R]. DE900001449, 1990.
  • 2Shankle A, Maiello R. The feasibility of detecting corrosion in electric fuzes using the thermal tansient technique[R]. AD-A221385, 1990.
  • 3周彬,徐振相,秦志春,等.瞬态脉冲无损性验证试验研究[C]..中国兵工学会第11届火工烟火学术年会论文集.西安:中国兵器工业第213研究所,2001.363-367.
  • 4胡学先,胡轶.电火工品的感度控制和预报[J].火工品,1999(2):39-42. 被引量:5