摘要
Double inlet version pulse tube is analyzed and potential direct current flow is revealed;improvement method of multi--double--inlet version is proposed. An experiment system wasset up. Through eXPeriment, multi--double--inlet version was proved effective to lower therefrigeration temperature: test shows 37K lowest temperature for two double inlet valve and59K lowest temperature for one double inlet valve. This pulse tube has 9.5W/77K coolingcapacity using 55mL valveless. The concept of multi--double--inlet was proposed here for thefirst time.
Double inlet version pulse tube is analyzed and potential direct current flow is revealed;improvement method of multi--double--inlet version is proposed. An experiment system wasset up. Through eXPeriment, multi--double--inlet version was proved effective to lower therefrigeration temperature: test shows 37K lowest temperature for two double inlet valve and59K lowest temperature for one double inlet valve. This pulse tube has 9.5W/77K coolingcapacity using 55mL valveless. The concept of multi--double--inlet was proposed here for thefirst time.
出处
《工程热物理学报》
EI
CAS
CSCD
北大核心
1999年第2期147-150,共4页
Journal of Engineering Thermophysics
基金
博士后基金
国家超导中心资助