以四川广安发电有限责任公司2×600MW机组制氢设备为例,分析了发电机制氢系统在运行当中突然停车的原因,给出了相应的处理办法。
Taking the hydrogen generation equipment of 2×600MW unit of Sichuan Guangan Power Generation Corporation Limited as example,the reasons of the sudden stoppage of the hydrogen generation system during operation were analyzed,and relevant treatment methods were given.
出处
《华电技术》
CAS
2010年第5期24-25,共2页
HUADIAN TECHNOLOGY
关键词
制氢设备
电解槽
联跳
故障
报警
hydrogen generation equipment
electrolytic tank
intertrip
fault
alarm