摘要 基于大功率全控型电力电子器件GTO的静止无功补偿装置具有自关断特性,在以DSP控制技术的支持下,通过实时检测电网无功功率的变化,自动发出GTO通/断控制脉冲,快速投切电容器,实现对供电线路无功功率的跟踪调节。该装置比普通晶闸管补偿装置(TSC)的可靠性高。在实现三相共补与分相补偿时,具有响应速度快、控制简单、噪音和损耗小、可靠性高、结构简练等优点。 A static var compensator based on high-power full-controlled power electronic device GTO has the self-shutdown feature.Supported by DSP control technology,any change of reactive power in the power grid can be detected in real-time,and sent to GTO automatically with on-off control pulse to achieve the tracking and adjusting of reactive power in the supply line.The device has a higher reliability than the ordinary thyristor compensator(TSC).It provides the advantages of fast response,simple control scheme,low noise,low loss,high reliability and so on if the compensations of three phases and single phase are realized.
作者 王易平
出处 《现代电子技术》 2010年第11期160-163,共4页 Modern Electronics Technique
基金 科技部中小企业技术创新基金项目(08C2622601562)
关键词 全控型电力电子器件GTO DSP 功率因数 静止无功补偿装置 full-controlled power electronic device GTO DSP power factor static var compensator
  • 相关文献

参考文献7

  • 1黄家善.电力电子技术[M].北京:机械工业出版社,2009.
  • 2陈国呈 周勤利.变频技术研究.上海大学自动化学院学报,1995,(6):23-26.
  • 3刘文华,陈建业,王仲鸿,王新超,李承业,刘毓,王旬,李向荣.采用GTO的新型静止无功发生器[J].电力系统自动化,1997,21(3):24-28. 被引量:25
  • 4王正元.面向新世纪的电力电子技术[J].自动化信息,2002(1):8-11. 被引量:1
  • 5SCHAUDER C D,MEHTA H.Vector analysis and control of advanced static VAR compensators[C] //Fifth International Conference on AC and DC Power Transmission.London:[s.n.] ,1991:266-272.
  • 6GYUGYI L,SCHAUDER C D,WILLIAS S L.Unified power flow controller:a new approach to power transmission control[J].IEEE Trans.on Power Delivery,1995,10(2):1085-1093.
  • 7HOCHGRAF C,LASSETER R H.STATCOM controls for operation with unbalanced voltage[J].IEEE Trans.on Power Delivery,1998,13(2):538-544.

共引文献32

同被引文献3

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部