期刊文献+

电感耦合等离子体原子发射光谱法测定钨铁中砷锑铋 被引量:9

Determination of arsenic,antimony,bismuth in ferro-tungsten by inductively coupled plasma atomic emission spectrometry
下载PDF
导出
摘要 研究了电感耦合等离子体原子发射光谱法(ICP-AES)同时测定钨铁中砷、锑、铋含量的分析方法。试样经草酸—过氧化氢分解后,在混酸条件下,钨生成钨酸沉淀与试液分离。经沉淀分离后,试液中钨的含量小于150μg/mL时对测定没有干扰。采用背景校正方式并结合基体匹配方法可以消除少量钨对谱线的干扰。该方法已应用于钨铁中砷、锑、铋含量的测定,加标回收率在95%~105%之间,相对标准偏差为0.86%~3.6%。 The simultaneous determination of arsenic,antimony and bismuth in ferrotungsten was studied by inductively coupled plasma atomic emission spectrometry.The sample was decomposed with oxalic acid and hydrogen peroxide.In the medium of mixed acid,tungsten was converted to tungstate precipitates and thus separated from sample solution.When residual tungsten in sample solution was less than 150 μg/mL,it did not interfere in the determination.The interference of residual tungsten could be eliminated by the background correction mode and matrix matching.The proposed method has been applied to the determination of arsenic,antimony and bismuth in ferro-tungsten,with the recoveries of 95 %-105 %,and the relative standard deviation(RSD) of 0.86 %-3.6 %.
出处 《冶金分析》 CAS CSCD 北大核心 2010年第5期65-67,共3页 Metallurgical Analysis
关键词 电感耦合等离子体原子发射光谱法 钨铁 inductively coupled plasma atomic emission spectrometry ferro-tungsten arsenic antimony bismuth
  • 相关文献

参考文献5

二级参考文献7

  • 1许修禄,张凤华,张静涛.高纯三氧化钨中28种痕量杂质元素的光谱分析[J].铀矿冶,1989,8(4):45-50. 被引量:5
  • 2蒋福生,分析化学,1983年,11卷,10期,736页
  • 3陈必有,李启华.工厂分析化验手册[M].北京:化学工业出版社,2002.
  • 4GB/T 7731.7-87 钨铁化学分析方法:苯基荧光酮光度法测定锡量[S].
  • 5GB/T 7731.9-87 钨铁化学分析方法:碘化铋光度法测定铋量[S].
  • 6GB/T 7731.14-88 钨铁化学分析方法:极谱法测定铅量[S].
  • 7杨秀环,汪丽,唐宝英,张展霞,贺柏龄,李劲枝,彭彤彤.ICP-AES直接测定钨产品中杂质元素[J].光谱学与光谱分析,1998,18(5):576-579. 被引量:22

共引文献39

同被引文献517

引证文献9

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部