光源色度参数的微机自动检测 被引量:1

Automatic Measurement of Light Source Colorimetry Parameters by Computer
下载PDF
导出
摘要 利用SD2000光谱仪在可见光范围内得到对于各个波长位置的相对光谱功率分布,根据色度学原理及CIE关于色度方面的有关推荐文件计算出光源的色度坐标,从而实现对多种光源色度参数的自动检测,解决了人们利用手工测量很难实现对光源色度参数进行有效检测的问题,取点波长间隔平均为△λ=0.38nm,提高了光源色度参数的精度. An application of personal computer control technique for automatic measurement of the eolour parameters of the light sources and its realization were introduced. By using the SD2000 spectrometer, the distribution value of the relative power of spectrum in correspondence with each wavelength location within 380-780 nm can be obtained. According to colorimetry principle and CIE about the relevant recommendation in the aspect of eolorimeter calculating file, the colour coordinate of light sources can be calculated and the problems of manual measurement of the colour parameters of the light sources can be solved. The precision of the colour parameters is improved by calculating the step of wavelength around 0.38 nm.
出处 《常熟理工学院学报》 2010年第4期55-58,共4页 Journal of Changshu Institute of Technology
基金 国家自然科学基金(No.10947130) 江苏省教育厅基金(No.09KJB140001) 常熟理工学院预研基金 常熟理工学院博士科研启动基金资助项目
关键词 相对光谱功率 三刺激值 色度坐标 the relative power of spectrum trietimulus values the colour coordinate
  • 相关文献

参考文献1

  • 1John Walkenbach,Brian Underdahl.中文版Excel 2002宝典[M].北京:电子工业出版社,2002:442-511.

同被引文献6

  • 1周德成,刘木清,韩磊,周小丽.光源的光效实验研究[J].照明工程学报,2006,17(1):7-9. 被引量:3
  • 2[日]照明学会.照叫下册[M].夸农.杨燕.第:版.北京:科学出版社,2005.
  • 3孙建民.电气照明技术[M].北京:中国建筑工业出版社,2004.
  • 4谢秀颖,郭宏祥.电气照明技术[M].第二版.北京:中国电力出版社,2011.
  • 5马文蔚,周雨青,解希顺.物理学教科.下册[M].第二版.北京:商等教育出版社,2006.
  • 6刘金清,陈顺凡,郑孔华.光源参数的微机自动检测[J].光电子技术与信息,2004,17(1):48-51. 被引量:3