期刊文献+

石墨炉原子吸收分光光度法直接测定全血中镍 被引量:10

Direct determination of nickel in whole blood by graphite furnace atomic absorption spectrometry
原文传递
导出
摘要 目的:建立石墨炉原子吸收分光光度法测定全血中镍的方法。方法:以0.15 g/L Mg(NO3)2/0.1%Triton X-100/0.2%HNO3(V/V)混合液为稀释液、1 mg/ml钯溶液为基体改进剂,对血液适当稀释后,直接用石墨炉原子吸收分光光度法测定镍的含量。结果:方法最低检出限(n=10)为0.92μg/L,平均特征质量为23.6~28.5pg/0.0044(A),线性范围为0μg/L~160μg/L,相对标准偏差0.6%~3.9%,回收率为99.9%~103.0%。结论:方法具有简便、快速、回收率高、精密度高的优点,适用于全血中镍含量的测定。 Objective:To establish a new method for determination of nickel in whole blood by graphite urnace atomic absorption spectrometry.Methods:A mixture of 0.15 g/L Mg(NO3)2/0.1%Triton X-100/0.2%HNO3(V/V) was proposed as the diluent,1 mg/ml Pd was proposed as the modifier.After the blood samples were diluted with the diluent,the concentration of nickel was directly detected by graphite urnace atomic absorption spectrometry.Results:For the optimized conditions,the experimentally determined LOD(limit of detection)(n=10) was 0.92 μg/L.The average characteristic mass was 23.6~28.5pg/0.0044ABS.The line range was 0 μg/L~160 μg/L.The relative standard deviations of the method was 0.6%~3.9%.The recoveries of this method were 99.9%~103.0%.Conclusion:The method is simple,fast,of high recovery and high precision.So it can be applied to determine the nickel in whole blood.
出处 《中国卫生检验杂志》 CAS 2010年第5期1005-1006,共2页 Chinese Journal of Health Laboratory Technology
基金 广东省医学科研基金项目(A2009060)
关键词 石墨炉原子吸收 全血 GF AAS Whole blood Nickel
  • 相关文献

参考文献2

二级参考文献1

共引文献2

同被引文献60

引证文献10

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史