立式储罐基底隔震的基本理论 被引量:19

Theoretical study on seismic isolation of storage tanks
下载PDF
导出
摘要 鉴于目前储罐基底的隔震研究大都是在Haroun模型的基础上进行的.本文以储罐基底隔震为基础,从储罐的晃动、刚性运动、液固耦联弹性运动出发,根据储罐结构所满足的速度势和边界条件,选择合理的势函数,研究储罐动水压力、波高、基底剪力和弯矩的动响应理论表达.利用相同激励下原型罐和等效力学模型罐基底剪力和弯矩等效原则,求出储罐分析力学模型的等效质量及相对质心高度,建立了隔震三质点控制体系简化分析的力学模型,给出了储罐抗震设计参数波高、基底剪力和弯矩简化分析表达.由Harmilton原理出发,考虑晃动和罐——液耦联振动周期相差较大,将两者作为不耦联运动,建立了隔震体系的运动方程.并对2×104m3和15×104m3储罐隔震和非隔震地震响应进行了时程分析研究,结果表明,基底隔震体系起到了很好的隔震效应. Based on the seismic isolation study of the storage tanks,starting with sloshing,rigid motion and fluid-structure coupling motion of the tanks,the dynamic response theory of hydrodynamic pressure,sloshing wave,base shear and overturning moment of the storage tanks was studied.Rational potential function was selected according to the velocity potential and boundary conditions that the structure of storage tanks satisfied.The equivalent mass and the relative height of mass center were given by using the same base shear and overturning moment of the liquid tank system and equivalent mechanical model when subjected to the same ground motion,and a three centralized particles mechanics analysis model was established.The simplified expressions of sloshing wave,base shear and overturning moment were given as well.The motion equation of the seismic system was established according to Harmilton principle.The earthquake responses of 2 × 104 m3and 15 × 104 m3 isolated and non-isolated tanks were analyzed by adopting the time history method.The numerical result shows that the base isolation seismic system exhibits good performance of seismic isolation.
出处 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2010年第4期639-643,共5页 Journal of Harbin Institute of Technology
基金 辽宁省教育厅科技基金资助项目(2009A151)
关键词 立式储罐 隔震 势函数 地震响应 vertical storage tank isolation potential function earthquake response
  • 相关文献

参考文献12

  • 1周锡元,阎维明,杨润林.建筑结构的隔震、减振和振动控制[J].建筑结构学报,2002,23(2):2-12. 被引量:235
  • 2韦树莲.必须重视大型石油储罐的抗震问题[J].国际地震动态,1995,16(3):17-21. 被引量:6
  • 3CHALHOUB M S, KELLY J M. Shake table test of cylindrical water tank in base isolated structures [ J ]. Journal of Structural Engineering, ASCE, 1990,116 (7) : 1451 - 1472.
  • 4LIANG B, TANG J X. Vibration studies of base isolated storage tanks [ J ]. Computers and structures, 1994, 52 : 1051 - 1059.
  • 5ZAYAS V S, LOW S S, MAHIN S A. Simple pedulum technique for achieve seismic isolation. [ J ]. Earthquake Spetra, 1990,6(2) :317 -333.
  • 6MALHOTRA P K. New method for seismic base isolation of liquid storage tanks [ J ]. Earthquake Engineering and Structural Dynamics, 1997,26:839 - 847.
  • 7MALHOTRA P K. Seismic strengthening of liquid-storage tanks with energy-dissipating anchors [ J ]. Journal of structural Engineering, ASCE, 1998, 124 ( 4 ) : 405 - 414.
  • 8WANG Y P,TENG M C,CHUNG K W. Seismic isolation of rigid cylindrical tanks using friction pendulum beating [J]. Earthquake Engineering and Structural Dynamics, 2001,30 : 1083 - 1099.
  • 9CHOK H, KIM M K, LLM Y M, et al. Seismic response of base-isolated liquid storage ta-nks considering fluid-structure-soil interaction in time domain [ J]. Soil Dynamics & Earthquakes Engineering, 2004,24 ( 11 ) : 839 - 852.
  • 10JADHAV M B, JANGID R S. Response of base-isolated liquid storage tanks [ J ]. Shock and Vibra-tion, 2004, 11:33 -45.

二级参考文献30

  • 1周锡元.建筑结构抗震设防策略的发展[J].工程抗震,1997(1):1-3. 被引量:14
  • 2刘季,孙作玉.结构可变阻尼半主动控制[J].地震工程与工程振动,1997,17(2):92-97. 被引量:20
  • 3MALHOTRA P K. Method for seismic base isolation of liquid-storage tanks [J]. J Struct Engrg, ASCE, 1997,123:113 - 116.
  • 4HAROUN M A. Assesment of seismic harzard to liquid storage tanks at port facilities[ A]. Proc1990 PolA Seismic Workshop[C]. [s. l.]:[s.n.],1991.
  • 5MALHOTRA P K. New method for seismic isolation of liquid- storage tanks [ J ]. J Earthquake Engrg Struct Dyn, 1997,26:839 - 847.
  • 6KELLY J M. Aseismic base isolation: review and bibliography[J]. Soil Dyn Earthq Eng, 1986, 5(3):202 -216.
  • 7HAROUN M A, HOUSNER G W. Dynamic interaction of liquid storage tanks and foundation soil [ A ]. Proc 2nd EMD Speciality Conf[ C]. SCE Atlanta: Georgia, 1981.
  • 8MALHOTRA P K. Method for seismic base isolation of liquid- storage tanks [J]. J Struct Engrg ASCE, 1997,123:113 - 116.
  • 9MALHOTRA P K. Seismic strengthening of liquid - storage tanks with energy- dissipating anchores [J]. JStruct Engrg ASCE, 1998, 124:405 -414.
  • 10HAROUN M A, HOUSNER G W. Dynamic interaction of liquid storage tanks and foundation soil, Proc. 2nd EMD Speciality Conf.

共引文献278