在高寒地区冬季,直接空冷系统的防冻成了直接空冷机组安全、经济运行的首要任务。通过直接空冷凝汽器冻结机理分析,开展直接空冷系统冬季防冻技术研究,并结合山西漳山直接空冷系统实际情况,提出相应的防冻措施。
Winter in extreme cold areas, anti-freeze of direct air-cooling condenser system is the primary task of a direct air-cooling unit safe and economic operation. We propose some corresponding measures of anti-freezing, through analyzing the freeze mechanism of direct air-cooling condenser, studying the anti-freeze technology of direct air-cooling condenser system, and combining the reality of direct air-cooling condenser system in zhangshan Shanxi.