Reappraisement and refinement of zircon U-Pb isotope and trace element analyses by LA-ICP-MS 被引量:1023

Reappraisement and refinement of zircon U-Pb isotope and trace element analyses by LA-ICP-MS
原文传递
导出
摘要 A protocol was established for simultaneous measurements of zircon U-Pb ages and trace elements by LA-ICP-MS at spot sizes of 16 32 μm.This was accomplished by introducing N 2 into ICP to increase the sensitivity.The obtained U-Pb ages for zircon standards GJ-1,TEMORA and SK10-2 are consistent with the preferred values within about 1% uncertainty (2σ) by simple external calibration against zircon standard 91500.Different data reduction softwares could yield different uncertainties for calculation of U-Pb ages.The commercially available program GLITTER4.4 could apply an improper uncertainty calculation strategy,but it may yield artificial high precisions for single analyses.Our trace element analyses indicate that Si is not an ideal internal standard for zircon when calibrated against the NIST glasses.Calibration against the NIST glasses using Si as an internal standard,a systematic deviation of 10% 30% was found for most trace elements including Zr.However,the trace element compositions of zircon can be accurately measured by calibration against multiple reference materials with natural compositions (e.g.,BCR-2G,BHVO-2G and BIR-1G),or calibration against NIST SRM 610 and using Zr as an internal standard.Analyses of two pieces of GJ-1 demonstrate that it is relatively homogenous for most trace elements (except for Ti). A protocol was established for simultaneous measurements of zircon U-Pb ages and trace elements by LA-ICP-MS at spot sizes of 16 32 μm.This was accomplished by introducing N 2 into ICP to increase the sensitivity.The obtained U-Pb ages for zircon standards GJ-1,TEMORA and SK10-2 are consistent with the preferred values within about 1% uncertainty (2σ) by simple external calibration against zircon standard 91500.Different data reduction softwares could yield different uncertainties for calculation of U-Pb ages.The commercially available program GLITTER4.4 could apply an improper uncertainty calculation strategy,but it may yield artificial high precisions for single analyses.Our trace element analyses indicate that Si is not an ideal internal standard for zircon when calibrated against the NIST glasses.Calibration against the NIST glasses using Si as an internal standard,a systematic deviation of 10% 30% was found for most trace elements including Zr.However,the trace element compositions of zircon can be accurately measured by calibration against multiple reference materials with natural compositions (e.g.,BCR-2G,BHVO-2G and BIR-1G),or calibration against NIST SRM 610 and using Zr as an internal standard.Analyses of two pieces of GJ-1 demonstrate that it is relatively homogenous for most trace elements (except for Ti).
出处 《Chinese Science Bulletin》 SCIE EI CAS 2010年第15期1535-1546,共12页
基金 supported by the National Natural Science Foundation of China (GrantNos. 40821061,90914007,40576030 and 90714010) the State Administration of Foreign Expert Affairs of China (Grant No. B07039) the Special Fund for Basic Scientific Research of Central Colleges,China University of Geosciences
关键词 PB同位素 微量元素 元素分析 ICP MS法 锆石 LA 固体火箭发动机 Zircon,U-Pb age,trace element,uncertainty,LA-ICP-MS
  • 相关文献

参考文献2

二级参考文献24

  • 1Hoskin P W O.Minor and trace element analysis of natural zircon (ZrSiO4) by SIMS and laser ablation ICP-MS: A consideration and comparison of two broadly competitive techniques[].J Trace Micropro Techn.1998
  • 2Simon E J,Norman J P,William L G,et al.The application of laser ablation-inductively coupled plasma-mass spectrometry to in-situ U-Pb zircon geochronology[].Chemical Geology.2004
  • 3Wilde S A,Vally J W,Peck W H,et al.Evidence from detrital zircons for the existence of continental crust and oceans on the Earth 4.4 Gyr ago[].Nature.2001
  • 4Günther D,Heinrich C A.Comparison of the ablation behavior of 266 nm Nd : YAG and 193 nm ArF excimer laser for LA-ICP-MS analysis[].Journal of Analytical Atomic Spectrometry.1999
  • 5Chang Z S,Jeffery D V,William C M,et al.U-Pb dating of zircon by LA-ICP-MS[].Geochem Geophys Geosystems.2006
  • 6Horn I,Rudnick R L,McDonough W F.Precise elemental and isotope ratio determination by simultaneous solution nebulization and laser ablation-ICP-MS: application to U-Pb geochronology[].Chemical Geology.2000
  • 7Black L P,Kamo S L,Allen C M,et al.TEMORA 1: A new zircon standard for Phanerozoic U-Pb geochronology[].Chemical Geology.2003
  • 8Gao S,Liu X M,Yuan H L,et al.Analysis of forty-two major and trace elements of USGS and NIST SRM glasses by LA-ICP-MS[].Geostandard Newslett.2002
  • 9Antonio S,Larry M H,Thomas C,et al.In situ petrographic thin section U-Pb dating of zircon, monazite, and titanite using laser abla- tion-MC-ICP-MS[].Inter J Mass Spectro.2006
  • 10Watson E B,Harrison T M.Zircon thermometer reveals minimum melting condition on earlier Earth[].Science.2005

共引文献357

同被引文献12991

引证文献1023

二级引证文献5644

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部