期刊文献+

考虑磁路饱和及集肤效应的异步风力发电机组暂态性能分析 被引量:4

TRANSIENT PERFORMANCES ANALYSIS OF WIND TURBINE SYSTEM WITH INDUCTION GENERATOR INCLUDING FLUX SATURATION & SKIN EFFECT
下载PDF
导出
摘要 为准确分析异步发电机不同详细模型对大型风电机组暂态性能的影响,该文结合2个质量块的风力机传动链等效模型,分别建立了笼型异步发电机考虑主磁路、定转子漏磁路饱和以及集肤效应影响的风电机组数学模型。针对大型风电机组在机械大扰动和电网电压骤降情况下,利用Matlab/Simulink平台对机组在不同数学模型描述时的暂态过程进行了仿真比较。结果表明,尤其在电网电压骤降时,电机磁路饱和对机组暂态运行性能的影响较为显著。 In order to analyze correctly the effect of different models for induction generators on the transient performances of large wind power generation, Wind turbine driven squirrel cage induction generator (SCIG) models taking into account both main and leakage flux saturation and skin effect were proposed.A two-mass lump equivalent model of a wind turbine shaft system was also used to considering shaft flexibility.Hie transient behaviors of the wind generator system with the different models were investigated and compared with the software platform Matlab/Simulink, under conditions of a large mechancical disturbance and a grid voltage sag, respectively.Simulation results have shown that the effect of the flux saturation is obvious on the transient behavious of the wind power generator system, especially for a grid voltage sag studies.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2010年第3期373-379,共7页 Acta Energiae Solaris Sinica
基金 国家自然科学基金(50607022)
关键词 风力发电 磁路饱和 集肤效应 异步发电机 暂态 wind power generation flux saturation skin effect induction generator transient
  • 相关文献

参考文献16

  • 1Clemens Jauch Julijia Matevosyan,Thomas Ackermann Sigrid Bolik.International comparison of requirements for connection of wind turbines to power systems[J].Wind Energy,2005,8:295-306.
  • 2迟永宁,刘燕华,王伟胜,陈默子,戴慧珠.风电接入对电力系统的影响[J].电网技术,2007,31(3):77-81. 被引量:499
  • 3Chen Z.Issues of connecting wind farms into power systems[A].2005 IEEE/PES Transmission and Distribution Conference& Exhibition:Asia and Pacific[C] ,Dalian,China,2005.
  • 4Bispo D,Martins L,Neto de Resende J T,et al.A new strategy for induction machine modeling taking into account the magnetic saturation[J].IEEE Trans Ind Appl,2001,37:1710-1719.
  • 5邓建国,罗德荣.电压骤降时三相感应电动机瞬态分析[J].电机技术,2003(4):6-8. 被引量:3
  • 6谢可夫.瞬时电压骤降时三相感应电动机瞬态分析[J].湖南师范大学自然科学学报,2003,26(4):47-50. 被引量:7
  • 7林友杰,吴汉光.考虑主磁路饱和时的异步电机d-q-n模型[J].中小型电机,2005,32(6):11-14. 被引量:3
  • 8Li H,Chen Z,Han L.Comparison and evaluation of induction generator models in wind turbine systems for transient stability of power system[A].2006 International Conference on Power System Technology[C] ,Chongqing,China,Powercon,2006.
  • 9Divya K C,Rao P S N.Study of dynamic behavior of grid connected induction generators[A].IEEE Power Engineering Society General Meeting[C] ,Denver,Colorado,USA,2004,2200-2205.
  • 10李东东,陈陈.风力发电机组动态模型研究[J].中国电机工程学报,2005,25(3):115-119. 被引量:182

二级参考文献50

共引文献686

同被引文献42

  • 1付立军,马伟明,刘德志,王东,张波涛,肖飞.十二/三相感应发电机的数值仿真与试验[J].电工技术学报,2005,20(6):6-10. 被引量:15
  • 2向大为,杨顺昌,冉立.电网对称故障时双馈感应发电机不脱网运行的励磁控制策略(英文)[J].中国电机工程学报,2006,26(3):164-170. 被引量:90
  • 3王昌存,李伟力,程鹏,孙秋霞.场路耦合双馈感应风力发电机负载性能的分析与计算[J].微电机,2007,40(6):6-10. 被引量:3
  • 4唐任远(Tang Renyuan).现代永磁电机理论与设计(Modern permanent magnet machines-Theory and design)[M].北京:机械工业出版社(Beijing:China Machine Press),1997.
  • 5Muljadi E,Butterfield C P,Parsons B. Effect of variable speed wind turbine generator on stability of a weak grid[J].{H}IEEE Transactions on Energy Conversion,2007,(01):29-36.
  • 6Lopez J,Sanchis P,Roboam X. Dynamic behavior of the doubly fed induction generator during three-phase voltage dips[J].{H}IEEE Transactions on Energy Conversion,2007,(02):709-717.
  • 7Fajardo L A,Iov R F,Medina R A. Induction generator model in phase coordinates for fault ride-through capability studies of wind turbines[A].Denmark:European Conference on Power Electronics and Applications,2007.1-10.
  • 8Perdana A,Carlson O,Persson J. Dynamic response of grid-connected wind turbine with doubly fed induction generator during disturbances[A].Nicolaos Cutululis:Nordic Wind Power Conference,2004.1-7.
  • 9De-Jesus J M F. A model for saturation in induction machines[J].{H}IEEE Transactions on Energy Conversion,1988,(03):682-688.
  • 10Hu J,He Y,Xu L. Improved control of DFIG systems during network unbalance using PI-R current regulators[J].{H}IEEE Transactions on Industrial Electronics,2009,(02):439-451.

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部