摘要 本文给出了自然通风潜力评估方法,根据此方法计算出了我国典型地区的自然通风潜力并对自然通风的影响因素进行了分析。根据计算结果得出结论:不同地区的自然通风有效小时数一般占全年总时间的20%~40%左右。影响自然通风潜力的因素是室外气象参数,但是不同地区其主要影响因素不同。寒冷地区主要是温度过低而湿热地区则主要是温度和湿度过高。随着室内得热量的上升,各地区自然通风有效时数呈下降趋势。但是各个地区下降的幅度不同:广州地区下降的最为明显而哈尔滨地区下降幅度最小。 A method of natural ventilation potential analysis of different regions in china was presented in this paper. Based on this method, the result of the effectiveness of natural ventilation in typical regions was calculated and the influence factors on the natural ventilation potential was analyses. According to calculation, the result is that the effective number of hours of natural ventilation in different parts is about 20%-40%. Factor affecting the potential of natural ventilation if outdoor meteorological parameters, but in different regions its main influencing factors different. In cold regions, low temperature is the main influencing factor and in hot and humid regions the main influencing factor is high temperature and humidity. With the indoor heat rising, the effective number of hours decline. However the decrease in various regions is different: Guangzhou is the most obvious and Harbin is the smallest.
出处 《建筑热能通风空调》 2010年第2期85-88,共4页 Building Energy & Environment
关键词 自然通风潜力 潜力分析 有效小时数 natural ventilation potential, potential analysis, the effective number of hours
  • 相关文献

参考文献4

二级参考文献33

  • 1[1]ALLARD F (ed.). Natural Ventilation in Buildings[M].Janes and James, London, 1998.
  • 2[2]IEA-ECB&CS Annex 35. Principles of hybrid ventilation[M]. Aalborg University, Denmark.2002.
  • 3[3]ASHRAE. ASHRAE Handbook:Fundamentals[M].ASHRAE, 1997.
  • 4[4]BARBAT M,RICHALET V, GUARRACINO G. Approach of the indoor air quality characterization in three specific buildings[A], EPIC' 98[C]. France: Lyon, 1998.
  • 5[5]asic Observatoire des marches: la gestion technique de batiment[J], Bati High-Tech.Janvier/Fevrier 1997,51.
  • 6[6]ISO Standard 7730,Moderate thermal environments, Determination of the PMV and PPD indices and specification of the conditions for thermal comfort[S]. ISO, 1984.
  • 7[7]ASHRAE Standard 55-1992,Thermal environmental conditions for human occupancy (ANSI approved)[S]. ASHRAE,1992.
  • 8[8]BRUANT M,GUARRACINO G,MICHEL P,et al. Impact of a global control of bioclimatic buildings in terms of energy consumption and building performance[A]. 4th European Conference on Solar Energy in Architecture and Urban Planning[C]. Berlin, 1996.
  • 9[9]ANDERSEN K T, Natural ventilation by thermal buoyancy with temperature stratification[A],Proc. ROOMVENT' 98[C], Sweden, 1998.
  • 10[10]DU PONT P, MORRILL J. Residential indoor air quality and energy efficiency[R].ACEEE,Washington D.C., 1989.

共引文献35

同被引文献17

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部