摘要 介绍了石英挠性伺服加速度计和研制的低频振动适调器组成了低频振动标准套组,在0.1~100Hz的振动频率范围内,能够把微弱、噪声较重的加速度信号,调理成信噪比较强、较稳定的信号。为低频振动加速度的量值复现、基标准装置的稳定性考核和量值溯源等提供了有力的保证,此标准套组还可广泛应用于其它低频振动测量领域。 A low-frequency vibration standard combination is composed of the quartz-flexible servo accelerometers and a self-developed conditioning amplifier. It can adjust the very weak and heavy noise aceelerometer signal to a strong and stable signal to noise ratio. It provides a powerful guarantee for low frequency vibration value replicable and vibration value stability assessment and vibration value traceability of the vibration standard devices. The low frequency vibration standard combination can applied in many other low frequency vibration field.
出处 《计量学报》 CSCD 北大核心 2010年第3期238-240,共3页 Acta Metrologica Sinica
关键词 计量学 石英挠性伺服加速度计 低频振动 适调放大器 低频振动标准套组 Metrology Quartz-flexible servo accelerometers Low Frequency Vibration Conditioning amplifier Lowfrequency vibration standard combination
  • 相关文献

参考文献3

  • 1张兰 ,刘永远 ,李邦清 .石英挠性加速度计输出饱和故障分析[J].战术导弹控制技术,2005(1):51-53. 被引量:2
  • 2戴莲瑾.精密测量低频振动石英挠性伺服加速度计.计量学报,1987,8(3):208-213.
  • 3郭振勤 段尚枢 王衍贵 等.石英电容伺服加速度计.哈尔宾工业大学学报,1985,(6):58-65.

共引文献1

同被引文献19

  • 1乔仁晓,孟晓风,贺忠江,徐永.精密离心机输出特性建模与误差分析[J].计量学报,2009,30(2):144-147. 被引量:3
  • 2王武立.石英挠性伺服加速度计的原理与应用[J].世界电子元器件,1996(10):40-42. 被引量:5
  • 3胡红波.低频振动副基准振动激励系统反馈控制的研究[D].北京:中国计量科学研究院,2008.
  • 4Liu Y H,Huang Y J,et al.The Design and Implementation of Proportional Feedback Controller for the Distortion Improvement of Vibrator in Low Frequency Motion[J].Journal of low frequency noise,vibration and active control,2003,23 (3):173-181.
  • 5JJG 233-2008,压电加速度计国家计量检定规程[S].
  • 6于梅.低频超低频振动计量技术的研究与展望[J].振动与冲击,2007,26(11):83-86. 被引量:27
  • 7IEEEStandard 528 -2001, IEEE Standard for Inertial Sensor Termi- nology, 2001.
  • 8IEEE Standard 1293TM -1998( R2008 ), IEEE Standard Specifica- tion Format Guide and Test Procedure for Linear, Single - Axis, Nongyroseopie Accelerometers, 2008.
  • 9IEEE Standard 836 - 2009, IEEE Reeommended Practice for Preci- sion Centrifuge Testing of Linear Aeeelerometers, 2009.
  • 10ISO 5347 - 8 : 1993 ( E ) , Methods for the Calibration of Vibration and Shock Pick - Ups - Part 8 : Primary Calibration by Dual Centri- fuge First Edition, 1993.

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部