医用诊断X线球管焦点性能检测装置的研制与应用 被引量:3

Development and utility of focal spot performance test device for medical diagnosis X-ray tube
下载PDF
导出
摘要 目的研制一种医用诊断X线球管焦点性能检测装置(简称检测装置)。方法根据国际IEC60336:2005标准要求,自主研制具有X线焦点中心线定位及进行焦点狭缝照相、针孔照相和星卡照相的检测装置,并对其进行焦点性能检测应用研究。结果检测装置能对X线焦点中心线进行定量调节定位,焦点中心线定位调节次数一般为2~3次,并可获得国际IEC60336:2005标准要求的焦点狭缝像、针孔像和星卡像。结论研制的检测装置焦点中心线定位精度高、功能全、操作简便、易于推广。 Objective To develop a test device, and to evaluate the focal spot performance for medical diagnosis X-ray tube. Methods According to the needs of the latest IEC standard IEC60336:2005, a focal spot performance test device with locating the X-ray centerline of a focal spot was self-developed and was used to produce the foeal spot slit images, focal spot pinhole images and focal spot star pattern images. The performance of focal spot was evaluated using the test device. Results To use the test device, the quantitative adjusting position of X-ray focal spot centerline was achieved. The quantitative adjusting position were generally repeated 2-3 times, and the focal spot slit images, focal spot pinhole images and focal spot star pattern images for meeting requirements of the IEC standard IEC60336 = 2005 were acquired. Conclusion The test device for positioning the X ray focal spot centerline has high accuracy and full-function, and is easy to operate and promote.
出处 《中国医学影像技术》 CSCD 北大核心 2010年第5期943-946,共4页 Chinese Journal of Medical Imaging Technology
基金 山东省科学技术发展计划重点项目(2004GG2202137) 山东省自然科学基金(Q2006C01)
关键词 X线球管 焦点性能 检测装置 研制 X ray tube Focal spot performance Test device Development
  • 相关文献

参考文献8

  • 1Medical electrical equipment-X-ray tube assemblies for medical diagnosis-Characteristics of focal spots,IEC 60336.2005:11-61.
  • 2国家食品药品监督管理局.YY/T 0063-2007医用电器设备医用诊断X线组件焦点特性.北京:中国标准出版社,2007:1-18.
  • 3Tuchyna T,Paix D.A CMOS image sensor method of focal spot size measurement.Australas Phys Eng Sci Med,2004,27(2):63-68.
  • 4中华人民共和国卫生部.WS-T 189-1999医用X射线诊断设备影像质量控制检测规范.北京:中国标准出版社,2000:5-6.
  • 5金华勇.医用X射线管的焦点测量中应注意的几个问题[J].计量与测试技术,2006,33(7):32-33. 被引量:7
  • 6唐建,蒋力培,邓双成,黄民双,黄军芬.医用X线成像系统的数字化进展[J].中国医学影像技术,2008,24(S1):4-7. 被引量:16
  • 7Rong XJ,Krugh KT,Shepard SJ,et al.Measurement of focal spot size with slit camera using computed radiography and flat-panel based digital detectors.Med Phys,2003,30(7):1768-1775.
  • 8Abe S,Negishi T,Fukaya M,et al.Measurement of focal spot in X-ray tube using imaging plate.Nippon Hoshasen Gijutsu Gakkai Zasshi,2004,60(8):1132-1138.