摘要 将基波分析法应用到基于移相控制的串联谐振变换器,以电路稳态模型为基础计算出变换器的电压增益、电路阻抗、谐振电容电压和谐振电感电流、电压电流应力及功率,得到这些量与工作频率、占空比及等效负载品质因数之间的数学表达式,并通过仿真图形进行直观显示。最后通过搭建的电路进行了实验验证。 The fundamental wave method is applied to analyze series resonant converter based on phase-shifted control.According to the steady state model,the expressions of voltage conversion ratio,circuit impedance,resonant inductance current and resonant capacitor voltage,voltage and current stresses against switching frequency are derived.The simulation diagrams are given to demonstrate their relationship.The experimental results verify the correctness of the analysis.
出处 《电力电子技术》 CSCD 北大核心 2010年第2期34-36,共3页 Power Electronics
基金 河北省自然科学基金资助项目(E2008000777) 河北省教育厅科学研究重点资助项目(ZH2007103)~~
关键词 变换器 串联谐振 移相控制 基波分析法 converter series resonant phase-shifted control fundamental wave method
  • 相关文献

参考文献2

  • 1J P Vandelae,P D Ziogas.A DC/DC PWM Series Resonant Converter operated at Resonant Frequency[J].IEEE Trans.on Industrial Electronics,1988,35(3):451-460.
  • 2Erickson,Robert W.Fundamentals of Power Electronics.Second Edition[M].Secaucus,NJ,USA:Kluwer Academic Publishers,2000.

同被引文献28

  • 1陈柬,陆治国.移相全桥软开关变换器拓扑分析[J].重庆大学学报(自然科学版),2005,28(12):27-31. 被引量:8
  • 2章涛,阮新波.输入串联输出并联全桥变换器的均压均流的一种方法[J].中国电机工程学报,2005,25(24):47-50. 被引量:29
  • 3李骏,范春菊.基于小波分析的电缆-架空线混合输电线路行波故障测距方法[J].电网技术,2006,30(9):92-97. 被引量:45
  • 4Yang Zhou,Dao Zhuojiang,Yu Fenwang.The development of HVDC transmission system[C]//Digital Manufacturing and Automation (ICDMA).GuiLin: IEEE,2012:907-910.
  • 5Sha Deshang, Guo Zhiqiang, Liao Xiaozhong. Cross feed back output-current-sharing control for input-series-output-parallel modular DC-DC converters [J]. IEEE Transactions on Power Electronics, 2010, 25(11): 2762-2771.
  • 6Giri R,Ayyanar R,Mohan N.Common duty ratio control of Input series connected modular dc-dc converters with active Input Voltage and Load Current sharing[C]//IEEE Applied Power Electronics Conference.Miami Beach: IEEE,2003:322-326.
  • 7Ayyanar R,Giri R,Mohan N.Active input voltage and load current sharing in input-series output-parallel connected modular dc-dc converters using dynamic Input Voltage reference scheme[J].IEEE Transactions on Power Electronics,2004,19(6):1462-1472.
  • 8Kim J W,You J S,Cho B H.Modeling,control,and design of input-series output-parallel connected converter for high-speed-train power system[J].IEEE Trans. on Industrial Electronics,2001,48(3):536-544.
  • 9Shenoy P S,Krein P T.Local control of an ISOP push-pull converter with uneven Load sharing[C]//IEEE Power and Energy Conference.Urbana-Champaign:IEEE,2010:70-76.
  • 10Fan Haifeng,Li Hui.A distributed control of Input-series Output-parallel bidrectional dc-dc converter modules applied for 20kVA solid state transformer[C]//IEEE Applied Power Electronics Conference.Fort Worth:IEEE,2011:939-945.

引证文献5

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部