某电厂引风机改型方案研究 被引量:6

Study on Retrofitting Project of the Induced Draft Fan in Some Power Plant
下载PDF
导出
摘要 基于引风机性能试验数据,提出引风机三种改型方案,并进行改型设计参数计算,对比分析各改型方案的技术特点,最终确定将甲侧引风机改造为Y4-60-14№25F风机;改造后风机效率提高12%左右,节电率高达20%左右,经济效益明显。 Based on the data of induced draft fan performance test,three retrofitting projects of the induced draft fan are introduced,and retrofitting design parameters are determined carefully.Technical features of three retrofitting projects are contrasted and analyzed.Finally,the right induced draft fan is retrofitted into Y4-60-14№25F.After retrofit,the efficiency of the induced draft fan is raised by about twelve per cent,energy saving rate is up to about twenty per cent,economic benefit is prominent.
出处 《节能技术》 CAS 2010年第2期187-189,192,共4页 Energy Conservation Technology
关键词 引风机 节能 风量 风压 改型方案 induced draft fan energy conservation air flow air pressure retrofitting design