期刊文献+

Garton效应对膜纸复合绝缘电容器介损测量值的影响及对策 被引量:22

Influence of Garton Effect on the Measurement Values of Dielectric Loss of Film-paper Composite Dielectric Capacitor and Some Countermeasures
下载PDF
导出
摘要 介质损耗因数(tanδ)的测量是判断电气设备绝缘情况较灵敏、有效的方法。介绍了绝缘理论中的Garton效应,分析了Garton效应对膜纸复合绝缘电容器介质损耗因数tanδ的影响,提出了现场试验中判断设备发生Garton效应的方法以及相应对策。 The measurement of dielectric dissipation factor(tanδ) is a sensitive and effective approach to judge the electrical insulation conditions of power equipments.The Garton effect in the insulation theory was described,and the influence of the effect on the measurement of dielectric dissipation factor(tanδ) of film-paper composite dielectric capacitors was analyzed.Some methods to judge if Garton effect occurs in power equipments in field tests were proposed and corresponding countermeasures were discussed.
出处 《绝缘材料》 CAS 北大核心 2010年第1期71-74,共4页 Insulating Materials
关键词 GARTON效应 膜纸复合绝缘 电容器 介质损耗因数 Garton effect film-paper composite dielectric capacitor dielectric dissipation factor
  • 相关文献

参考文献6

二级参考文献9

  • 1朱洁.电力电容器的电场问题[J].电力电容器,1985,7(2):19-19.
  • 2宋明兰.不同介质及其搭配方式对电容器性能的影响[J].电力电容器,1985,7(2):26-26.
  • 3许亚德.加热对聚丙烯薄膜为主的固体介质与液体介质组成的绝缘系统损耗因数的改变[J].电力电容器,1985,7(2):56-57.
  • 4高桥健 向井贞喜 井上靖雄.电力电容器及其介质材料[J].电力电容器,1985,7(2):58-68.
  • 5常宪民 王友功 李丽琴.油—膜相互作用对聚丙烯薄膜击穿性能的影响[J].电力电容器,1985,7(3):1-6.
  • 6Mammootty K P. Ramu T S [J]. IEEE Trans. on Elec.Insulation, 1983, 18(5): 541-550.
  • 7王友功 李丽琴 常宪民 等.聚丙烯薄膜与绝缘油相溶性的实验研究[J].电力电容器,1984,6(3):10-16.
  • 8DL/T 596-1996.电力设备预防性试验规程[S],1996.
  • 9DL/T 536-1993.耦合电容器及电容分压器订货技术条件[S],1993.