摘要
对一台卧式快装锅炉后管板高温区多处出现的裂纹进行了宏观检验,结合该锅炉结构和制造问题及运行工况做了综合分析,认为裂纹是由于制造工艺没有满足技术标准的要求,运行过程水质处理不当所引起的,并提出了处理措施,时间证明效果良好。
Quick installation of a horizontal high-temperature boiler tube plate after the various mountain areas are carried out macro-crack test,In conjunction with the boiler structure and manufacturing issues and a comprehensive analysis of operating conditions,That the crack is due to manufacturing process does not meet,Running water Treatment caused by improper handling,And proposed measures,Good results.
出处
《装备制造技术》
2010年第5期167-167,173,共2页
Equipment Manufacturing Technology
关键词
表面裂纹
锅炉水处理
处理措施
surface crack
boiler water treatment
treatment measures