摘要 设计并搭建了带回热器的商用跨临界CO2水-水热泵热水器试验系统,并依据相应的国家标准对试验系统进行了多个工况的循环性能试验研究。试验结果表明,名义工况下出水温度85℃时制热COPh值为2.82,最大负荷工况下出水温度65℃时制热COPh值为3.68。冷却水进水温度越高,系统效率越低。同时试验结果表明,CO2作为制冷剂在热泵热水器的应用中更具有优势。 A commercial water source heat pump water heater system using CO2 transcritical cycle with inner heat exchanger was described.A series of experiment for the heat pump were carride out according to the National Standards for commercial heat pump.The experimental results show that the transcritical CO2 heat pump is advantageous over those conventional refrigerants heat pump.On the process of experiment,a heating–COP of 2.82 under nominal working condition and 3.68 under maximum load working condition were achieved for the transcritical CO2 heat pump when the outlet water temperature are 85℃ and 65℃,respectively.Heating-COP decrease with the increase of the inlet cooling water temperature.CO2 is more suitable for the heat pump system than the conventional refrigerants.
出处 《流体机械》 CSCD 北大核心 2010年第5期63-66,共4页 Fluid Machinery
基金 国家高技术研究发展计划(863计划)项目(2006AA05Z234) 中国博士后科学基金项目(20070421115) 广东省教育部产学研项目(2007B090400033)
关键词 CO2 跨临界循环 热泵热水器 COP CO2 transcritical cycle heat pump COP
  • 相关文献

参考文献13

  • 1Lorentzen G.Revival of carbon dioxide as a refrigerant[J].Inter.J.Refrig.,1993,17(5):229-301.
  • 2Neksa P.CO2-heat pump system[J].Inter.J.Refrig.,2002,25(4):421-477.
  • 3Bullard C W,Yin J M,Hrnjak P S.Transcritical CO2 mobile heat pump and A/C system experimental and model results[R].ACRC&University of Illinois,USA.
  • 4Petter Neksa.CO2 heat pump systems[J].Inter.J.Refrig.,2002,25:421-427.
  • 5Richter M R.Experimental results of transcritical CO2 heat pump for residential application[J].Energy,2003,28:1005-1019.
  • 6Rin Yun,YHb,Reinhard Radermacher,Convective gas cooling heat transfer and pressure drop characteristics of supercritical CO2/oil mixture in a minichannel tube[J].Inter.J.Heat and Mass Transfer,2007,50:4796-4804.
  • 7Saikawa M,Hashimoto Kobayakawa T.Development of prototype of CO2 heat pump water heater for residential use[A].Proceeding of the 4th IIR Gustav Lorentzen conference on natural working fluids[C].2000.51-58.
  • 8Mukaiyama H,Kuwabara.Experimental results and evaluation of residential CO2 heat pump water heater[A].Proceeding of the 4th IIR Gustav Lorentzen conference on natural working fluids[C].2000.67-74.
  • 9Mukaiyama H.Development of CO2compressor and its applicaition system[A].Proceeding of the 7th International energy agency heat pump conference[C].2002.1137-1146.
  • 10Endoh K.Instant hot-water supply heat-pump water heater using CO2 refrigerant homes[A].Proceeding of the 7th IIR Gustav Lorentzen Conference on Natural Working Fluids[C].2006.27-30.

共引文献27

同被引文献80

引证文献7

二级引证文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部