期刊文献+

再循环冷却塔辐射供冷的试验研究 被引量:5

Recycling Cooling Tower of the Experimental Study of Radiation Cooling
下载PDF
导出
摘要 针对我国中湿度地区设计搭建了再循环冷却塔实验台,并与辐射末端相结合,阐述了其工作原理并对再循环冷却塔进行了性能测试。依照过渡季节和夏季工况,对再循环冷却塔供冷性能进行了测试,并结合测试结果对不同冷源的供冷方案进行能耗分析,挖掘了再循环冷却塔在实际应用中的节能潜力。经计算得出,在不同条件下该系统方案相比传统机械制冷供冷方案可节能40%~60%。同时以期使更多的工程设计人员了解该供冷模式及设计思路,为工程设计人员提供有益的参考。 Humidity in the region of our country has set up a recycling cooling tower designed to test-bed with the end of radiation combined,the principle of its work was expounded,as well as recycling of cooling tower performance test.In accordance with the transitional seasons and in summer conditions,to recycle cooling performance of cooling towers tested,and combined with the cold test results for different sources of cooling energy analysis program,excavation of the recycling cooling tower in the practical application of energy-saving potential.Calculate that,in the program of the system under different conditions compared to traditional mechanical refrigeration cooling solution can 40%~60% energy saving.At the same time in order to allow more engineers to understand the cooling mode and design ideas for engineering design provides a useful reference.
机构地区 西安工程大学
出处 《流体机械》 CSCD 北大核心 2010年第5期67-71,共5页 Fluid Machinery
关键词 蒸发冷却 再循环冷却塔 辐射供冷 能耗分析 evaporative cooling recycling cooling tower radiation cooling energy consumption analysis
  • 相关文献

参考文献10

二级参考文献84

共引文献260

同被引文献50

  • 1汤跃,秦武轩,袁寿其.基于变工况运行的泵能耗指标计算方法[J].农业工程学报,2009,25(3):46-49. 被引量:11
  • 2屈元,黄翔.间接蒸发冷却器热工计算数学模型及验证[J].流体机械,2004,32(11):50-53. 被引量:9
  • 3黄翔,周斌,于向阳,张新利,肖鸣远.新疆地区三级蒸发冷却空调系统工程应用分析[J].暖通空调,2005,35(7):104-107. 被引量:26
  • 4朱冬生,涂爱民,李元希,等.蒸发式冷却器/闭式冷却塔的应用前景及其设计计算[C].中国制冷学会2007学术年会论文集,2007.
  • 5Rodin S I. Use of Genetic Algorithms for Optimal Con- trol of Bulk Water Supply[ J]. Journal of Irrigation and Drainage Engineering,2004,130 ( 5 ) : 357-365.
  • 6Yagi S, Shiba S. Application of Genetic Algorithms and Fuzzy Control to a Combined Sewer Pumping Sta- tion [ J ]. Water Science and Technology, 1999, 39 (9) :217-224.
  • 7Xavier Escaler, Eduard Egusquizaa, Mohamed Far- hat, et al. Detecti on of cavitati on in hydraulic tur- bines [ J ]. Mechanical Systems and Signal Processing, 2006, 20 (4) : 983-1007.
  • 8Hyun joo Han, Jeong Tai Kim, Hyun Tae Ahn , et al. A three-dimensional performance analysis of all- glass vacuum tubes with coaxial fluid conduit [ J ]. In- ternational Communications in Heat and Mass Trans- fer, 2008 , 35 (5) : 589-596 .
  • 9Sabbagh E, Sina G. A Model for Optimal Real-time Computer Control of Pumping Stations in Irrigation Systems [ J ]. Computers and Electronics in Agricul- ture, 1988, 3(11) :119-133.
  • 10Elliott D, Uri S. Optimal operation of the pumping stations in the Kinnereth-Eshkol section of the nation- al water carrier [ J]. Journal of H~drology, 1976,28 (2) :271-288.

引证文献5

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部