X射线二极管在2~6keV能区的灵敏度退化研究

Sensitivity degradation of X-ray diodes in 2 to 6 keV
下载PDF
导出
摘要 利用北京同步辐射装置4B7B束线,在2.1-5.9 keV能区,对"强光一号"加速器Z箍缩实验中常用的Al和Au阴极X射线二极管进行了谱响应标定。对比了不同阴极材料(Au和Al)、加工方式(蒸镀Al和机械加工固体Al)及使用条件(参与实验发次)对探测器谱响应分散性及退化程度的影响。长期储存后的镀Au阴极仍有较好的谱响应一致性,但灵敏度退化明显,比文献报道新鲜Au阴极数据低70%以上,使用中还会进一步降低。Al阴极在保存和使用中的灵敏度退化相对较轻。新鲜的固体Al阴极谱响应分散性较小,灵敏度较文献报道数据略高,使用过10-40发次并保存9个月后灵敏度平均下降约20%-30%。镀Al阴极的谱响应分散性较大,相对偏差可达20%。初步探讨了定期更换以减轻灵敏度退化影响的可行性。 Spectral responses of aluminum-and gold-cathode X-ray diodes,commonly used in Z-pinch experiments of Qiangguang-I generator,have been calibrated on the 4B7B beamline of Beijing Synchrotron Radiation Facility,with a spectral range of 2.1 to 5.9 keV.Results of different kinds of cathodes,as well as other published data,are compared to check the effect of cathode material,preparation process and usage conditions on the degradation and dispersivity of the sensitivity.Evaporated gold cathodes stored in dry air for several years still have quite uniform spectral responses,while also with a large fall that their responses are only 20% to 25% of those reported data for fresh gold cathodes.Used gold cathodes even show a further fall in sensitivities.The aluminum cathodes exhibit much less degradation in response.Newly-prepared solid aluminum cathodes also have responses with low dispersivity,and the sensitivities are a little higher than those reported data.When used for 10~40 shots in a month and stored for 9 months,the responses fall by 20%~30%.Evaporated aluminum cathodes show larger response variation that the standard deviation may reach 20%.The method,which uses solid,sufficiently oxidated aluminum cathodes and changes them every 10~20 shots,is proposed to mitigate the sensitivity degradation effects.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2010年第6期1285-1290,共6页 High Power Laser and Particle Beams
基金 国防预研项目资助课题 国家自然科学基金项目(10475065)
关键词 X射线二极管 标定 光阴极 灵敏度 退化 X-ray diode calibration photocathode sensitivity degradation
  • 相关文献

参考文献13

  • 1易荣清,杨国洪,崔延莉,杜华冰,韦敏习,董建军,赵屹东,崔明启,郑雷.北京同步辐射3B3中能束线X射线探测系统性能研究[J].物理学报,2006,55(12):6287-6292. 被引量:16
  • 2崔延莉,易荣清,杜华冰,赵屹东,崔明启,郑雷.XRD探测器和滤片在北京同步辐射3B3中能束线上的标定[J].高能物理与核物理,2006,30(9):912-915. 被引量:1
  • 3甘新式,杨家敏,易荣清,张继彦,赵屹东,赵阳,崔明启,邓爱红.邻苯二钾酸氢铊晶体积分衍射效率的标定[J].强激光与粒子束,2007,19(11):1827-1831. 被引量:10
  • 4张东清,崔明启,朱佩平,赵屹东,崔聪悟.在同步辐射软X射线能区硅光电二极管的自标定[J].高能物理与核物理,2000,24(6):578-584. 被引量:5
  • 5Scholze F,Rabus H,Ulm G.Spectral responsivity of silicon photodiodes:high-accuracy measurement and improved self calibration in the soft X-ray spectral range[C] //Proc of SPIE.1996,2808:534-543.
  • 6Krumrey M,Büermann L,Hoffmann M,et al.Absolute responsivity of silicon photodiodes in the X-ray range[C] // Proc 8th Int Conf on Synchrotron Radiation Instrumentation.2003:861-864.
  • 7Idzorek G C,Bartlett R J.Silicon photodiode characterization from 1 eV to 10 keV[C] //Proc of SPIE.1997,3114:349-356.
  • 8Henke B L,Gullikson E M,Davis J C.X-ray interactions:photoabsorption,scattering,transmission,and reflection at E=50-30,000 eV,Z=1-92[J].Atomic Data and Nuclear Data Tables,1993,54(2):181-342.
  • 9Henke B L,Knauer J P,Premaratne K.The characterization of x-ray photocathodes in the 0.1-10-keV photon energy region[J].J Appl Phys,1981,52(3):1509-1520.
  • 10Day R H,Lee P,Saloman E B,et al.Photoelectric quantum efficiencies and filter window absorption coefficients from 20 eV to 10 keV[J].J Appl Phys,1981,52(11):6965-6973.

二级参考文献22

  • 1孙可煦,易容清,成金秀,王宏斌,马洪良,牟丹民,李亚轩,崔艳莉,唐道源,郑志坚.激光腔靶X射线面、体发射特性实验研究[J].物理学报,1994,43(5):748-755. 被引量:3
  • 2孙可煦,江少恩,易荣清,崔延莉,丁永坤,刘慎业.X射线二极管时间特性研究[J].物理学报,2006,55(1):68-75. 被引量:12
  • 3韦敏习,杨家敏,杨国洪.平面晶体积分衍射效率实验标定[J].强激光与粒子束,2006,18(2):219-222. 被引量:10
  • 4邓健.国家高技术863-416-4.3.1课题97年度进展报告[M].,1997.69-80.
  • 5卢仁祥.用于激光等离子体实验的X光晶体谱仪[J].光学学报,1982,2(6):568-568.
  • 6邓,国家高技术 863-4 1 6-4 .3.1课题 97年度进展报告,1997年,69页
  • 7易荣清 孙可煦.强激光与粒子束,1996,4:202-202.
  • 8孙可煦 易荣清.物理学报,1997,46:191-191.
  • 9Henke B L,Knauer J P,Premaratne K 1981 J.Appl.Phys.52 1509
  • 10Henke B L,Smith J A 1977 J.Appl.Phys.48 1852

共引文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部