期刊文献+

超高压输电线路新型单端电流暂态保护的实现方法研究

An Approach to Non-unit Transient Protection of EHV Transimission Lines Based on Theory of Cosine-modulated Filter Banks
下载PDF
导出
摘要 概述了单端量暂态保护的研究现状,并对其存在的问题进行了探讨.研究发现利用多速率滤波器组理论对暂态信号分析具有的多分辨率、对高频信号高分辨力等优势能够较好地解决其原理和技术上的诸多问题.并提出了多速率滤波器组的一种有效实现方法,QuartusⅡ仿真表明它完全能够满足超高压保护实时性的要求.所提出的方法对建立超高压输电线路高速继电保护具有重要意义. This paper discusses the problem needed to be resolved presently in non-unit transient protection. A new non-communication protection technique for transmission lines based on the theory of multirate filter bank is proposed, which has many advantages such as frequency-division multiplexing, etc, It can effectively resolve many problems in this field. An effective approach to realization of multi-rate filter bank is also presented. The QuartusⅡ simulation shows that it meets the need of EHV protection. The approach given in the paper has practical value in the real protection of EHV.
出处 《湖南工程学院学报(自然科学版)》 2010年第2期5-8,共4页 Journal of Hunan Institute of Engineering(Natural Science Edition)
关键词 超高压输电线路 单端量暂态保护 多速率滤波器组 分布式算法 EHV transmission line non-unit transient protection multi-rate filter bank distributed arithmetic
  • 相关文献

参考文献7

二级参考文献29

  • 1薄志谦.新一代电力系统继电保护──暂态保护[J].电网技术,1996,20(3):34-36. 被引量:41
  • 2沈国荣,郑玉平.高压电网超高速继电保护技术的最新成就[J].中国电力,1996,29(11):85-90. 被引量:7
  • 3沈国荣.工频变化量方向继电器原理的研究[J].电力系统自动化,1983,(1):28-38.
  • 4田又涵.极性比较式行波方向保护的研究:硕士学位论文[M].西安:西安交通大学,1981..
  • 5董新洲.小波理论应用于输电线路行波保护研究:博士后研究工作报告[M].天津:天津大学,1998..
  • 6董新洲.小波理论应用于输电线路故障测距研究:博士学位论文[M].西安:西安交通大学,1996..
  • 7(美)崔锦泰 程正兴(译).小波分析导论[M].西安:西安交通大学出版社,1995..
  • 8徐丙寅.利用暂态行波的输电线路故障测距技术[M].西安:西安交通大学,1991..
  • 9薄志谦,International Conference on Advance in Power System Control Operation & Management,1995年
  • 10薄志谦,International Power Engineering Conference,1995年