摘要 为了现场快速检测牛奶溶液中四环素类抗生素的含量,对电极进行阳极氧化、氨基化、活化等一系列处理,将四环素核酸适体作为识别分子,共价固定于玻碳电极表面,构建出新型核酸适体生物传感器。传感器可以特异性结合标本中四环素类抗生素,并产生电化学信号,强度与抗生素浓度相关。其最低检测量是1μg/L,检测时间为5 m in。 A new aptamer biosensor for fast detection of tetracycline was established.Glassy carbon electrode(GCE) was modified by anode-oxidation,amino and activation process.The recognizable molecular aptamer was immobilized on the surface of GCE by the covalence connection.It could quickly detect the tetracycline in sample.Electrochemical signs from aptamer biosensor showed tetracycline concentration in sample.The detection limit was 1 μg/L and the detection time was 5 min.
出处 《生物加工过程》 CAS CSCD 2010年第3期48-52,共5页 Chinese Journal of Bioprocess Engineering
基金 科技部资助项目(2009GJA10047) 天津市科委资助项目(07ZHXHNC04500 09ZCZDSF04200)
关键词 核酸适体生物传感器 四环素 检测 aptamer biosensor tetracycline detection
  • 相关文献

参考文献11

  • 1Torres-Chavolla E,Alocilja E C.Aptasensors for detection of microbial and viral pathogens[J].Biosensors and Bioelectronics,2009,24(11):3175-3182.
  • 2Ellington A D,Szostak J W.In vitro selection of RNA molecules that bind specific ligands[J].Nature,1990,346:818-822.
  • 3Tuerk C,Gold L.Systematic evolution of ligands by exponential enrichment:RNA ligands to bacteriophage T4 DNA polymerase[J].Science,1990,249:505-510.
  • 4Senturk S,Temizel M.Clinical efficacy of rifamycin SV combined with oxytetracycline in the treatment of caseous lymphadenitis in sheep[J].Veterinary Record,2006,159(7):216-217.
  • 5Molina A,Molina M P,Althaus R L,et al.Residue persistence in sheep milk following antibiotic therapy[J].The Veterinary Journal,2003,165:84-89.
  • 6Oka H,Ito Y,Matsumoto H.Chromatographic analysis of tetracycline antibiotics in foods[J].Journal of Chromatography A,2000,882(1/2):109-133.
  • 7Tombelli S,Minunni M,Mascini M.Analytical applications of aptamers[J].Biosensors and Bioelectronics,2005,20:2424-2434.
  • 8De-los-Santos-Alvarez N,Lobo-Castan M J,Miranda-Ordieres A J,et al.Aptamers as recognition elements for label-free analytical devices[J].Trends in Analytical Chemistry,2008,27:437-446.
  • 9Yoshida W,Sode K,Ikebukuro K.Aptameric enzyme subunit for biosensing based on enzymatic activity measurement[J].Analytical Chemistry,2006,78:3296-3303.
  • 10Yoshida W,Sode K,Idebukuro K.Homogeneous DNA sensing using enzyme-inhibiting DNA aptamers[J].Biochem Biophys Res Comm,2006,348:245-252.

同被引文献214

引证文献8

二级引证文献64

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部