摘要 对具有四川电网内"两个第一"的普光气田220kV变电站的35kV配网接地方式进行了研究及总结。该站为四川电网内第一个主变压器35kV线圈采用三角形接线的变电站,为此两台主变压器共节省设备投资约360万元。该站为四川电网内第一个35kV中性点经中电阻接地、单相接地故障直接跳闸的配网系统,对今后类似工程的设计将起到较好的借鉴作用。 The grounding mode of 35 kV distribution network in 220 kV substation of Puguang gas field which has "Two Firsts" in Sichuan power grid is analyzed and summarized.Puguang 220 kV substation is the first substation that uses delta connection at 35 kV side of main transformer in Sichuan power grid,therefore,two mains transformers have saved the investment of the equipment about 3.6 million yuan.Also,it first uses medium resistance for 35kV neutral point grounding of distribution network in Sichuan power grid,and the protection equipment can trip as long as the single-phase ground fault happens.The design experiences can provide the reference for the design of subsequent project.
作者 刘永寿
出处 《四川电力技术》 2010年第3期81-83,共3页 Sichuan Electric Power Technology
关键词 主变压器 全星形接线 三角形接线 中电阻接地 main transformer totally star connection delta connection medium resistance grounding
  • 相关文献

参考文献3

  • 1电力工程电气设计手册[Z].北京:水利电力出版社,1989.
  • 2电力系统设计手册[z].北京:中国电力出版社,2000.
  • 3DL/T620-1997.交流电气装置的过电压保护和绝缘配合.[S].,..

共引文献32

同被引文献6

  • 1中国电力工程顾问集团中南电力设计院;中国电力工程顾问集团公司.电力工程地下金属构筑物防腐技术导则[S]北京:中国电力出版社,2007.
  • 2中国石化工程建设公司.石油化工装置防雷设计规范[S]北京:中国计划出版社,2011.
  • 3电力工业部电力科学研究院高压研究所.交流电气装置的接地[S]北京:中国电力出版社,1997.
  • 4电力工业部电力科学研究院高压研究所.交流电气装置的过电压保护和绝缘配合[S]北京:中国电力出版社,1997.
  • 5林晓光;代勇;徐崇浩.ALG防腐离子接地体接地效果模拟分析[J]中国电子情商,2009(03):50-51.
  • 6陈范娇;刁望敏;章正茂.风电场防雷接地技术探讨[J]中国防雷,2010(03):53-55.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部