摘要
直接进水样气相色谱法快速测定水中的硝基苯,分别采用2%QF-1+1.5OV-1ChromosorbWAW-DMCS(80-100目)(Ⅰ)和5%聚乙醇-6000101白色担体(40-60目)(Ⅱ)为固定相的两种不锈钢柱,FID检测器,对硝基苯完成分离,本法进样4μl的检测限为0.25mg/L,能满足应急污染监测的需要。对柱Ⅰ,提出了一种改善分离的方法.
A Rapid GC method for determination of the nitrobezene in water is studied. The water sample is injected directly into the 1102 GC equipped with FID. Two column,packed with 2%QF-1+1. 50V-1 ad-sorbed on chromosorb W AW-DMCS (80~100 mesh) or 5% polyethylene glycol 6000 on 101 white carrier (40~60 mesh) are compared. on the base of exper iments,this method is found to be accurate,rapid and sen-sitive enough for determining nitrobezene in water at ppm levels,and can be applied in emergency monitoring.A modified technique is proposed to improve the seperation of nitrobezene from water.
出处
《环境科学与技术》
CAS
CSCD
北大核心
1999年第1期43-45,共3页
Environmental Science & Technology
关键词
气相色谱法
硝基苯
应急监测
水质监测
Direct aqueous injection GC Nitrobezene Emergency monitoring