摘要
实施"油改电"以后,轮胎吊高架滑触线供电系统在实际使用暴露了一些问题。为此,进行了改进。揭示了原供电系统的问题及原因。从5个方面采取了安全措施。有效提高了轮胎吊高架滑触线供电系统的安全性。
After the reform of "electricity instead of oil",a few problems has revealed in the usage of the power supply system of the high support sliding line of the RTG.So improvement has been carried out.This paper analyses the problems and its reasons of the original power supply system,takes safety measures from 5 aspects,which has raised safety of the power supply system of the high support sliding line of the RTG.
出处
《港口科技》
2010年第5期20-21,共2页
Port Science & Technology
关键词
港口
轮胎吊
高架滑触线
供电系统
安全
port RTG high support sliding line power supply system safety