摘要
介绍了如何将核电厂相关设计规范应用于内陆核电厂最终热阱输热系统的机械通风冷却塔的等级划分,分析和总结了核级机械通风冷却塔的特殊设计和建造要求,并提出了核级机械通风冷却塔的设备鉴定过程,为我国自行设计和开发核级机械通风冷却塔提供借鉴和指导作用。
This paper described the nuclear power plant related design criterion classification of mechanical draft cooling tower used in inland nuclear power plant ultimate heat-sink systems,analyzed and summarized the special design and construction requirements of nuclear-classified mechanical draft cooling tower,and brought forward the qualification procedure of equipments in such cooling tower,and finally proposed a reference and guide for the design and development of domestic nuclear-classified mechanical draft cooling tower.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
2010年第3期92-95,101,共5页
Nuclear Power Engineering
关键词
内陆核电厂
机械通风冷却塔
设计
建造
Inland nuclear power plant
Mechanical draft cooling tower
Design
Construction