摘要 第三代核电AP1000因非能动理念的引入,使安全系统设计有了重大创新,机组安全性和经济性得到了大大提高。但是非能动理念并非局限于安全系统,非安全系统设计中同样也引入了非能动理念。通过对放射性气体废物系统的详细介绍,以及与传统压水堆废气处理方式的对比可以看出,非能动理念的引入,使放射性气体废物系统相比传统工艺有了很大改进,摆脱了对能动设备的依赖,处理方式由原来的压缩贮存衰变转变为活性碳滞留衰变,简化了工艺流程,提高了运行安全性。 The concept of passiveness,which has been generally used in the third-generation nuclear power technology AP1000,makes a great innovation in the design of the security systems,and the safety and economy have been greatly enhanced.However,this concept is used not only in safety systems,but also in the design of non-safety systems.Through the detailed introduction of the Gaseous Radwaste System,and the contrast with the traditional pressurized water reactors,it could be seen that the use of passiveness makes great innovation compared with tranditional technology.The operation does not depend on the active components,and the treatment of gaseous radwaste has been greatly improved from compress-store-decay to adsorb-decay by activated carbon.This innovation simplifies the process and improves the safety of operation.
作者 董波 高明石
出处 《核动力工程》 EI CAS CSCD 北大核心 2010年第3期128-131,共4页 Nuclear Power Engineering
关键词 AP1000 非能动 气体废物 AP1000 Passive Gaseous radwaste
  • 相关文献

参考文献1

二级参考文献4

  • 1郭亮天,史英霞,王瑞云,张瑞宝,田霖.用于核电站放射性惰性气体处理的常温活性炭滞留床研究[J].辐射防护,1994,14(1):15-24. 被引量:20
  • 2IAEA.Design of Off-gas and Air Cleaning System at Nuclear Power Plants.IAEA Technical Report Series No.274.1987
  • 3Moeller D W,Underhill D W.Review and Evaluation of Factors Affecting Noble Gas Adsorption on Activated Carbon.Nuclear Safety,1981.22(5):599
  • 4Siegwarth D P,Neulander C K,Pao R T,et al.Measurement of Dynamic Adsorption Coefficients for Noble Gases on Activated Carbon.Proceedings of 12th AEC Air Cleaning Conference.CONF-720823,1970.28-47

共引文献21

同被引文献23

引证文献8

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部