用复极性固定床电解槽处理偶氮染料废水,在正交试验确定的原水COD200mg/L、槽电压30V、停留时间2h、导电颗粒与绝缘颗粒体积比14的条件下,色度和COD去除率分别达到99%以上和78.4%~97.2%。
In the treatment of wastewater from azo dye production by electrolysis in a bipolar packed bed cell, the removal efficiencies of color and COD came up to over 99% and 78.4%~ 97.2% respectively under the conditions of 200mg/L of influent COD, 30V of cell tension, 2h of retention time and 1∶4 of conductive particles to insulating particles(V/V).