摘要 城市污水处理系统处于复杂的侵蚀环境中,受到生物腐蚀、化学腐蚀、物理腐蚀等多因素作用。已建及新建污水处理构筑物,为达到耐久性要求应采取必要的防护措施。以试验结果为依据,对试验采用的3种防腐方法:表面涂覆结晶类防水材料、表面涂覆非结晶类防水材料、表面涂覆硅烷类防水材料,利用GM(1,1)灰色模型对防护措施的效果进行了预测分析。试验及预测均表明表面涂覆防水材料能很好的提高混凝土构筑物的长期耐久性能。 Sewage treatment system operate in a complex environment,Bio-corrosion,chemical corrosion and physical erosion are affecting it. The Sewage treatment structures that have been completed and will be built,In order to achieve the durability requirements should take the neces- sary protective measures.Based on the experimental results,there are three kinds of anti-corrosion methods:coating crystallization materials,coat- ing non-crystallization materials,coating silanes materials.Based on GM(1,1),gray theory was established to predict the effects of anti-corrosion methods.The results show that coating water-proof material can well improve the durability of concrete structures.
出处 《混凝土》 CAS CSCD 北大核心 2010年第5期46-48,共3页 Concrete
关键词 灰色理论 GM(1 1) 污水环境 混凝土耐久性 gray theory GM(1 1) sewage environment concrete durability
  • 相关文献

参考文献6

二级参考文献51

  • 1范迪恩.在腐蚀条件下混凝土结构耐久性的设计[J].防腐蚀工程,1998,14(1):45-48. 被引量:3
  • 2李志国,葛勇,钮长仁.材料耐久性机理及控制的理论研究[J].哈尔滨建筑大学学报,1996,29(6):79-84. 被引量:5
  • 3陈六平.材料的微生物腐蚀破坏机制研究进展[J].江西科学,1996,14(1):59-66. 被引量:9
  • 4邓法庚,许如源.混凝土排水管的防腐[J].混凝土与水泥制品,1997(1):30-35. 被引量:5
  • 5THAER M.Wahshat sulfur mortar and polymer modified sulfur mortar lining for concrete sewer pipe[D].Iowa:Iowa State University,2001.
  • 6PARKER C.The corrosion of concrete-Isolation of a species of bacterium associated with the corrosion of concrete exposed to atmospheres containing hydrogen sulphide[J].Exp Biol Med Sci,1945,23 (3):14-17.
  • 7PARKER C.Mechanics of corrosion of concrete sewers by hydrogen sulfide[J].Sewage and Industrial Wastes,1951,23(10):1477-1485.
  • 8DAVIS J L,NICA D.Quantifying microbially induced deterioration of concrete:initial studies[J].International Biodeterioration and Biodegradation,2002,49(4):233-237.
  • 9ISLANDER R L,DEVINNY J S,MANSFIELD F.Microbial ecology of crown corrosion in sewers[J].Journal of Environmental Engineering,1991,(117):751-770.
  • 10MORI T,NONAKA T,TAZAKI K.Interactions of nutrients,moisture,and pH on microbial corrosion of concrete sewer pipes[J].Wat Res,1992,26(1),29-37.