摘要 本文报道一个光度法测定纳克量锡的新方法。在聚乙烯醇(PVA)存在下锡(Ⅳ)与钨酸盐和耐尔蓝(NB)反应形成离子缔合物,离子缔合物的最大吸收位于580nm,表观摩尔吸光系数ε值2.95×107L·mo1-1·cm-1,服从比耳定律范围0~2.0μg/L,检出限(3σ)0.083μg/L(n=10),对2.0μg/L锡测定的RSD为1.42%(n=11),离子缔合物至少稳定72h。考察了40多种共存离子的影响,大多数常见元素不干扰。测定锡的适宜条件[H2SO4]=1.20mo1/L,[WO2-4]=6.05×10-5mo1/L,[NB]=5.5×10-5mo1/L和PVA0.08%。本法已用于某些合金钢和锌合金中纳克量锡的测定,结果与推荐值吻合,回收率满意。 A new spectrophotometric method for the determination of nanogram amounts of tin(Ⅳ)is developed based on the reaction of tin(Ⅳ)with tungstate and nile blue(NB) to form and ion association complex in the presence of polyvinyl alcohol(PVA). The ion-association complex exhibits maxium absorptivity at 580nm with apparent molar absorption coefficient was 2.95×10 7L·mol -1 ·cm -1 . Beer's law was obeyed over the concentration range of 0 ̄2.0μg/L. The detection limit(3σ)is 0.083(g/L(n=10) and the relative standard deviation of 2.0μg/L of tin(Ⅳ)is 1.42%(n=11). The ion association complex is stable for at least 72h. Over 40 foreign ions were tested for interference. Most common ions do not interfere. The optimum conditions for the determination of tin(Ⅳ)are 1.20mol/L of H 2SO 4, 6.05×10 -5 mol/L of WO 2- 4, 5.5×10 -5 mol/L of NB and 0.08% PVA. The method has been applied to the determination of nanogram amounts of tin(Ⅳ)in some steels and zinc based alloys samples. The results obtained agree well with recommended values and the recovery is statisfied.
出处 《分析科学学报》 CAS CSCD 1999年第1期24-27,共4页 Journal of Analytical Science
关键词 钨酸盐 耐尔蓝 光度法 纳克量 测定 Tin, Tungstate, Nile blue, Spectrohotometry
  • 相关文献

参考文献5

共引文献13

同被引文献605

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部