期刊文献+

等电位更换110kV双回线路直线铁塔绝缘子 被引量:2

On-line Replacing Insulator for 110 kV Tangent Tower with Double Circuit Line
下载PDF
导出
摘要 针对110 kV线路小间距双回路垂直排列直线塔结构特点,论证了利用特制绝缘悬臂梯进入强电场等电位进行110ZGU1、110ZGU2型等双回路直线铁塔更换绝缘子串、更换附件、处理防振锤等工作的可行性,并介绍了相应的实施方法以及实用效果。完成了带电检修和消除缺陷的目的。彻底解决了110 kV小间距多回垂直排列塔无法进入等电位进行带电作业的难题。 According to structure characteristics of 110 kV tangent towers with small-distance double circuit transmission line,feasibility of on-line replacing of insulators for 110ZGU1 and 110ZGU2 tangent tower with insulated cantilever staircase was reasoned in this paper.Corresponding implementing steps and application effects were also introduced.The method given in this paper could complete on-line maintenance and eliminate defects,resolve problems for on-line working in equal potential for 110 kV tangent towers with small-distance double circuit transmission line.
作者 郝旭东 孙兵
出处 《华北电力技术》 CAS 2010年第6期42-48,共7页 North China Electric Power
关键词 110kV 双回路 直线塔 等电位 检修 消缺 110 kV double circuit tangent tower equal potential maintenance defect eliminating
  • 相关文献

参考文献6

  • 1万年安.带电作业技术[M].北京:中国电力出版社,2006.
  • 2厉国祥.带电作业三大规程汇编[M].太原:山西科学教育出版社,1978.
  • 3李如虎.带电作业工具受力分析和强度计算.东北电力技术,1990,(5).
  • 4李洪仁.带电作业用绝缘软梯.东北电力技术,1992,(2).
  • 5孙兵,李文和,李军田.地电位更换110kV线路小间距双回路耐张塔绝缘子串[J].电力技术,2009(11):28-33. 被引量:5
  • 6哈尔滨建筑工程学院,重庆建筑工程学院.材料力学[M].北京:高等教育出版社,1988.

共引文献5

同被引文献13

  • 1杨勇.带电更换110kV^220kV直线双串绝缘子的方法[J].云南电力技术,2006,34(1):45-46. 被引量:1
  • 2GB311.1-1997高压输变电设备的绝缘配合[S],1997.
  • 3DL/T966-2005送电线路带电作业技术导则[s],2005.
  • 4GB50545-2010110kV-750kV架空输电线路设计规范[S].2010.
  • 5陈国信,林丽雅.厦门电业局攻克110千伏同塔更换绝缘子难关[EB/OL].中国电力网,2007,11.
  • 6DL409-91电业安全工作规程(电力线路部分)[S].1991.
  • 7GB/T311.2-2002绝缘配合第2部分使用导则[S].2003.
  • 8GB/T20635-2006特殊环境条件高压用高压电器的技术要求[S].2006.
  • 9IEC60694-2002高压开关设备和控制设备常用规范[S].2002.
  • 10吴志成.110kV双回线路直线塔中相绝缘子的带电更换[J].供用电,2009,26(1):62-64. 被引量:2

引证文献2

二级引证文献4