摘要
目前,实验室废水排放不规范,特别是实验室的有机废水,含有大量的有毒有害物质,未经处理的排放将对环境造成严重的污染。本试验采用Fenton试剂法对实验室的有机废水进行处理,分析了亚铁投加量、过氧化氢投加量、pH值和反应时间等影响因素对处理效果的影响。确定了Fenton法处理实验室有机废水的最佳工艺参数,将为类似实验室有机废水处理提供借鉴。
Nowadays, the laboratory wastewater emission is disorder, especially organic laboratory wastewater contains a lot of toxic or hazardous material, and its untreated discharge will pollute the environment seriously. The Fenton method is used to deal with organic laboratory wastewater, and its influence factors with ferrous amount,hydrogen peroxide amount, pH, reaction time are analyzed. The best technological parameters are made sure. The study will provide the experience for treatment of similar organic laboratory wastewater.
出处
《矿冶》
CAS
2010年第2期88-90,共3页
Mining And Metallurgy