1Lichtwarek AM,Zeravik J,Pfeiffer UJ.Intrathoracieblood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation[J].Intensive Care Med,1992,18(3):142-147.
2Michani F,Boussat S,Chemla D.Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure[J].Am J Respir Crit Care Med,2000,162(1):134-138.
3Wiesenack C,Fiegl C,Keyser A,et al.Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients[J].Eur J Anaesthesiol,2005,22:658-665.
4Pinsky MR,Teboul JL.Assessment of indices of preload and volume responsiveness[J].Curr Opin Crit Care,2005,11:235-239.
5Rocoo M,Spadetta G,Morelli A,et al.A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation[J].Intensive Care Med,2004,30(1):82-87.
6Leomie RM,Pigott DW,Mihm FG.Measurement of cardiac output by transpulmonary artery thermodilution using a long radial artery catheter.A comparison with intermittent pulmonary artery thermodilution[J].Ansetheria,2004,59(6):590-594.
7Wiesenack C,Fiegl C,Keyser AC,et al.Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients[J].European Journal of Anaesthesiology,2005,22:658-665.
8Christoph K,Alban S,Luc W,et al.Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system[J].Critical Care,2008,12(3):82-89.
9Michael S,Claudia DS,Katharina B,et al.Prediction of volume response under open-chest conditions during coronary artery bypass surgery[J].Critical Care,2007,11(6):121-127.
10Makoto K,Masayoshi K,Takashi I,et al.Stroke Volume Variation as a Predictor of Intravascular Volume Depression and Possible Hypotension During the Early Postoperative Period After Esophagectomy[J].Annals of Surgical Oncology,2009,16(5):1371-1377.
二级参考文献6
1Tousignant CP, Walsh F, Mazer CD. The use of transesophageal echocardiography for preload assessment in critically ill patients. Anesth Analg, 2000, 90: 351-355.
2Bendjelid K, Romand JA. Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care. Intensive Care Med, 2003, 29:352-360.
3Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest, 2002, 121: 2000-2008.
4Reuter DA, Bayerlein J, Goepfert MS, et al. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med, 2003, 29 : 476-480.
5Hofer CK, Muller SM, Furrer L, et al. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off- pump coronary artery bypass grafting. Chest, 2005, 128: 848-854.
6Hanley JA, McNeil BJ. The meaning of use of the area under a receiver operating characteris-tic(ROC) curve. Radiology, 1982, 143 : 29-36.
2Ebert T, Hall J, Barney J, et al. The effects of increasing plasma coneentrateons of dexmedetomidine in humans [J]. Anesthesiology, 2000, 93(2): 382-394.
3Fairbanks CA, Stone IS, Wilcox GL. Pharmacological profiles of alpha 2 adrenergic receptor agonists identified using genetically altered mice and isobolographic analysis [J]. Pharmacol Ther, 2009, 123(2): 224-238.
4Farag E, Argalious M, Abd-Elsayed A, et al. The use of dexmedetomidine in anesthesia and intensive care: a review [J]. Curr Phann Des, 2012, 18(38) : 6257-6265.
5Ihmsen H, Sami TI. Dexmedetomidine. Pharmacokinetics and pharmacodynamics [J]. Anaesthesist, 2012, 61(12) : 1059- 1066.