1[1]Becker LB,Weisfeldt ML,Weil MH et al.The PULSE initiative:scientific priorities and strategic planning for resuscitation research and life saving therapies.Circulation,2002,105:2562-2570.
2[2]Zheng ZJ,Croft BJ,Giles WH,et al.Sudden cardiac death in the United States,1989 t0 1998,Circulation,2001,104:2158-2163.
3[3]Cobb LA,Fahrenbruch CE,Olsufka M,et al.Changing incidence of out -of-hospital ventricular fibrillation,1980-2000.JAMA,2002,288:2008-2013.
4[4]Weaver WD,Cobb LA,Hallstrom AP,et al.Factors influencing survival after out -of -hospital cardiac.J Am coll Cardiol,1986,7:752-757.
5[5]Brennan RT,Braslow A.Skill masteay in public CPR classes.Am J Emerg Med,1998,78:754-760.
6[6]Halperin HR,Paradis NA,Ornato PJ,et al.Improved hemodynamics with a novel chest compression device in a porcine model of cardiac arrest.Circulation,2002,106:11-538.
7[7]Halperin HR,Guerci D,Chandra N,et al.Vest inflation without simultaneous ventilation during cardiac arrest in dogs.Circulation,1986,74:1407-1415.
8[8]Ralston SH,Voorhees WD,Babbs CF,et al.Intrapulmonary epinephrine during prolonged cardiopulmonary resuscitation;imprmed regional blood flow and resuscitation in dogs.Ann Emerg Med,1984,13.79-86.
1Steen S,Olsso P. Treatment of out-of-hospital cardiac ar rest with LUCAS, a new device for automatic mechanical compression and active decompression resuscitation[J]. Resuscitation, 2006,67(1) :25-30.
2Weil MH, Fries M. In hospital cardiac arrest concise de- finitive review[J]. Critical Care Medicine, 2006,33 (12) : 2825-2830.
3Steen S,Liao Q,Pierre L,et al. Evaluation of LUCAS,a new device for automatic mechanical compression and ac- tive decompression resuscutaion[J]. Resuscitation, 2008, 55:285-299.
4Wolcke BB, Mauer DK. Comparison of standard cardiop- ulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of- hospital cardiac arrest [J]. Circulation, 2007, 108 .. 2201 2205.
5Abella BS, Alvarado JP, Myklebust H. Quality of cardiop- ulmonary resuscitation during in-hospital cardiac arrest [J]. JAMA,2005,25(18) :2321-2329.
6Krep H, Mamier M, Breil M, et al. Out-of-hospital car-diopulmonary resuscitation with the auto pulse system: a prospective observational study with a new load-distribu- ting band chest compression device [J]. Resuscitation, 2007,73..86-95.
7Ong ME,Ornato JP,Edwards DP,et al. Use of an auto- mated, load-distributing band chest compression device for out-of hospital cardiac arrest resuscitation[J]. JAMA, 2006,295 : 2629-2637.
8Hallstrom A, Rea TD, Sayre MR, et al. Manual chest com- pression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac ar- rest a randomized trial[J]. JAMA, 2006,295 : 2620-2628.
9keno F,Kaneda H, Hongo Y,et al. Augmentation of tis- sue perfusion by a novel compression device increases neurologically intact survival in a porcine model of pro- longed cardiac arrest [J]. Resuscitation, 2006, 68: 109- 118.
10Kaski JP, Tom6-Esteban MT, Mead-Regan S, et al. B-type natriuretic peptide predicts disease severity in children with hypertrophic cardiomyopathy [J]. Heart, 2008, 94.. 1307-1311.