摘要 结合对多台储罐底板漏磁检测过程中所发现与总结的问题,从扫查覆盖率的控制、缺陷方向性影响、底板剩磁影响、缺陷单板定位、超声方法复验和底板表面状况影响等六个方面,对如何做好底板腐蚀漏磁检测工作提出了一些意见和建议。 The present summary is about the problems encountered during the magnetic flux leaking(MFL) inspecting for many storage tanks. Six issues were discussed in brief including the controlling of the scanning coverage percentage, the directionality effect of defects, the effect of residual magnetism, the defect positioning on single floor, the rechecking cases using ultrasonic method and the effect of surface condition, etc. Some empirical recommendations and conclusions were proposed to promote the MFL inspection work of bottom floor corrosion.
出处 《无损检测》 2010年第6期450-453,共4页 Nondestructive Testing
关键词 漏磁检测 常压储罐 腐蚀 底板 Magnetic flux leakage testing Storage tank Corrosion Bottom plate
  • 相关文献

参考文献5

  • 1API 653-2001 Tank Inspection , Repair ,Alteration , and Reconstruction[S].
  • 2JB/T10765-2007无损检测常压金属储罐漏磁检测方法[S].
  • 3Santos J B, Perdigao F. Automatic defects classification-A contribution [J].NDT and E International, 2001,34(5) : 313--318.
  • 4Cameron N B. Recommended practice for magnetic flux leakage inspection of atmospheric storage tank floors[R]. UK: HSE Infoline,2006 : 21.
  • 5Marino A, Drury J C. A Comparison of the Magnetic Flux Leakage and Ultrasonic Methods in the Detection and Measurement of Corrosion Pitting in Ferrous Plate and Pipe[C]// 15th World Conference on Non--Destructive Testing. Rome: [s. n.], 2000 .- 701.