摘要 目的探讨影响非接触式眼压计(NCT)测量结果准确性的相关因素及寻求有效的护理措施。方法 2007年6月~2009年8月,对265例青光眼患者采用NCT进行眼压测量,其中男92例,女173例,年龄6~81岁,平均52.3岁。结果本组265例(345眼)中有71例(86眼)测量结果中出现不准确提示,测量失败率为24.9%。分析其影响因素主要为情绪紧张焦虑、眼睑睫毛遮挡、上眼睑皮松弛、眼压计喷头部不清洁、角膜表面干燥、水肿不平和视力不良、固视不好、操作者对测量者情绪的影响等。经采取相应的护理干预措施,包括安抚患者情绪,纠正患者错误检查姿势,维护及清洁机器等,达到纠正了不准确结果的目的。结论用非接触式眼压计测量眼压可受多种临床因素的影响,采取相应护理干预措施能提高测量的准确性。
出处 《当代护士(中旬刊)》 2010年第6期92-93,共2页 Modern Nurse
  • 相关文献

参考文献5

  • 1Rajak SN,Paul J,Sharma V,et al.Contamination of disposable tonometer prisms during tonometry[J].Eye,2006,20(3):358-361.
  • 2Segal WA,Pirnazar JR,Arens M,et al.Disinfection of GOldmann tonometers after contamination with hepatitis C virus[J]. Am J Ophthalmol,2001,131(2): 184-7.
  • 3Walia JS,Chronister CL.Possible iatrogenic transmission of Creutzfeldt-Jakob disease via tonometer tips:a review of the literature[J].Optometry, 2001,72(10) : 649-52.
  • 4Lim R, Dhillon B,Kurian KM,et al.Retention of corneal epithelial cells following Goldmann tonometry:implications for CJD risk[J].Br J Ophthalmol,2003,87(5):583-6.
  • 5张宇燕,孙兴怀.常见眼压计的临床评价[J].眼视光学杂志,2004,6(2):132-135. 被引量:31

二级参考文献29

  • 1Pandav SS,Sharma A,Gupta A,et al.Reliability of ProTon and Goldmann applanation tonometers in normal and postkeratoplasty eyes[J].Ophthalmology,2002,109(5):979-984.
  • 2Garzoz HJ,Chung HS,Lang Y,et al.Intraocular pressure and photorefractive keratectomy a comparison of three different tonometers[J].Cornea,2001,20(1):33-36.
  • 3Duch S,Serra A,Castanera J,et al.Tonometry after laser in situ keratomileusis treatment[J].J Glaucoma,2001,10(4):261-265.
  • 4Kaufmann C,Bachmann LM,Thiel MA.Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis[J].Invest Ophthalmol Vis Sci,2003,44(9):3790-3794.
  • 5Munoz LA,Perez AL,Rahhal MS,et al.Assessment of applanation tonometry after hyperopic laser in situ keratomileusis[J].Cornea,2002,21(2):156-160.
  • 6Copt RP,Tomas R,Mermoud A.Corneal thickness and normal tension glaucoma[J].Arch Ophthalmol,1999,117(1):14-16.
  • 7Dekker PW,Robert YCA,Kanngiesser H,et al.Principles of contact lens tonometry[J].International Ophthalmology,1998,22(2):105-111.
  • 8Shah S,Chatterjee A,Mathai M,et al.Relationship between corneal thickness and messured intraocular pressure in a general opthalmology clinic[J].Ophthalmology,1999,106(11):2154-2160.
  • 9Ventura ACS,Bohnke M,Mojon DS.Central corneal thickness measurements in patients with normal tension glaucoma,primary open angle flaucoma,pseudoexfoliation glaucoma,or ocular hypertension[J].Br J Ophthalmol,2001,85(6):792-795.
  • 10Brandt JD,Beiser JA,Kass MA,et al.Central corneal thickness in the ocular hypertension treatment study(OHTS)[J].Ophthalmology,2001,108(10):1779-1785.

共引文献30

同被引文献10

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部