应用AutoCAD在数字影像上进行下肢力线分析 被引量:1

Intra-and interobserver reliability of analysis of lower limb alignment on digital images using AutoCAD
原文传递
导出
摘要 目的 评价将数字影像直接导入AutoCAD进行力线分析的观察者间与观察者自身信度以及所耗时间,并与传统的X胶片测量方法进行对比.方法 对140膝采用以上两种方法进行前后位和全长相角度测量,每种方法平行测量三次,两名观察者分别独立测量.计算每种方法的观察者间和观察者自身ICC值,以Fisher转换Z检验将两种方法的ICC值进行对比,并将两种方法测量每侧膝所耗时间进行配对t检验.结果 观察者间ICC值AutoCAD法为0.942~0.993,传统胶片法为0.736~0.981,观察者自身ICC值AutoCAD 法为0.937~0.999,传统胶片法为0.759~0.951,对应ICC值AutoCAD法比X线胶片法高,大部分有显著差异(P〈0.01);两名观察者采用AutoCAD法测量一侧膝关节耗时较传统胶片法平均分别短89.6s和94.3s,均差异统计学意义(P〈0.01).结论应用AutoCAD在DR数字影像上进行下肢力线分析是一种快捷、可靠的方法. Objective To evaluate intra-and interobserver reliability of analysis of lower limb alignment on DR digital images using AutoCAD.Methods Angles on AP view and long leg view were measured three times by two trained observers separately using these two methods in 140 knees.The intra-and interobserver intraclass correlation coefficients with 95% CIs of two methods were calculated and compared with Fisher z transformation and Z test.Paired t test was used in comparing time consumption.Results For AutoCAD method,inter ICCs were 0.942? 0.993 ,intra ICCs were 0.937~0.999.For X-ray films method,inter ICCs were 0.736~0.981,intra ICCs were 0.759~0.951.Corresponding ICCs of AutoCAD method were higher than those of X-ray films method,most of which had significant differences(P〈0.01).The consuming time of two observers in measuring one knee using AutoCAD method was 89.6 seconds and 94.3 seconds shorter than those using X-ray films method respectively.Both had significant differences(P〈0.01).Conclusion It was a fast reliable method to assess lower limb alignment on DR digital images using AutoCAD.
出处 《中国基层医药》 CAS 2010年第11期1453-1455,I0001,共4页 Chinese Journal of Primary Medicine and Pharmacy
关键词 下肢力线 AUTOCAD 组内相关系数 观察者间信度 观察者自身信度 Lower limb alignment AutoCAD Intraclass correlation coefficient(ICC) Interobserver reliability Intraobserver reliability
  • 相关文献

参考文献6

二级参考文献24

  • 1王洁贞,韩兢,刘言训,丁守銮.Kappa统计量在一致性和重现性检验中的应用[J].山东医科大学学报,1996,34(3):209-212. 被引量:45
  • 2Landis JR, Koch GG. The measurement of observer agreement for Gategorical data. Biometrics, 1977.33 : 159-174.
  • 3Eric JH. Computer-assisted orthopaedic surgery a new paradigm. Tech Orthop,2003,18 (6) :221-229.
  • 4Taylor RH, Lavallee S, Burdea GC, et al. Registration for computer integrated surgery: methodology, start of the art. Computer integrated surgery. Cambridge:MIT Press, 1996,22(4) :77-97.
  • 5DiGioia AM 3rd,Jaramaz B, Colgan BD. Computer assisted orthopaedic surgery. Image guided and robotic assistive technologies. Clin Orthop Relat Res,1998,22(354) :8-16.
  • 6Bathis H, Perlick L, Tingart M, et al. Radiological results of image- based and non - image - based computer - assisted total knee arthro plasty. Int Orthop ,2004,12 (28) :87 - 90.
  • 7Whiteside LA. Soft tissue balancing: the knee. J Arthroplasty, 2002,17(4 Sup-pll ) :23-27.
  • 8Klein G R, Parvizi J, Papuri V R, et al. The effect of tibial polyethylene inserted sign on range ofmotion:evaluation ofin vivoknee kinematics by a computerized navigation system during totalknee ar- throplasty. J Arthroplasty ,2004,19 ( 8 ) :986-991.
  • 9Mahaluxmivala J,Bankes M J,Nicolai P,et al. The effect of surgeon experience on component positioning in 673 press fit condylarposterior cruciate-saerificing total knee arthroplasties. Arthroplasty,2001,16 (5) :635-640.
  • 10Mihalko W M, Boyle J, Clark L D, et al. The variability of intramedullary alignment of the femoral componentduring totalknee arthroplasty. J Arthroplasty,2005,20( 1 ) :25-28.

共引文献211

同被引文献5

  • 1Hsu RW, Himendo S, Coventry MB, et al. Normal axial a- lignment of the lower extremity and load-bearing distribution at the knee [J]. Clin Orthop, 1990, 255: 215-227.
  • 2Odenbring S, Egund N, Lindstrand A, et al. Cartilage regen- eration after pwoximal tibial osteotomy for medial gonarthro- sis: an arthroscopic, roentgenographic and histologic study [J]. Clin Orthop, 1992, 277: 210-216.
  • 3Csnale ST. Campbell's operation orthopaedics [J]. 9Ed. St. Louis:Mosby-Year Book Inc, 1998, 242-247.
  • 4杨广奇,杨旭峰,吴腾芳,温醒伟.Philips DR全脊柱立位摄影技术的探讨[J].影像诊断与介入放射学,2009,18(6):316-318. 被引量:9
  • 5秦民益,蒋青,胡毓亮,刘广月,吴琮琏.负重位全下肢成像技术研究及临床应用价值[J].中华放射学杂志,2002,36(9):845-846. 被引量:25

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部