摘要
介绍了CO2复合电极的研制及测定水中游离CO2浓度的方法。结果表明:该方法测定浑浊、有色、pH>8的水中游离CO2的浓度,在0.006~0.40mg/L范围内符合线性关系,相对平均偏差1.1%,较传统的滴定法便简、准确。
The tritura of CO 2 compounding electrode and the method of determinating the aquatic dissociate CO 2 concentration are introduced.The results show that the way we selected can determine the aquatic dissociate CO 2 in various water which is muddy,colourful and pH>8.Aquatic dissociate CO 2 can be well determined by this method in the range from 0.006mg/L to 0.40mg/L.This method can save time and is more simple and ready and accurate which compares with the traditional titrimetry.
出处
《山东建材学院学报》
1999年第1期25-27,共3页
Journal of Shandong Institute of Building Materials