Transient Performance of an Isolated Induction Generator under Unbalanced Loading Conditions
Transient Performance of an Isolated Induction Generator under Unbalanced Loading Conditions
摘要
This paper presents a new transient model ofa standalone (isolated) self excited induction generator (SEIG). This model is based on direct phase quantities and is suitable to study the performance of the generator under any balanced or unbalanced conditions. It includes a general load as well as general excitation capacitor model. The model has the advantage of connecting or disconnecting the neutral points of the generator electrical system with both excitation capacitors and load. Furthermore, a more accurate magnetization curve is used. Moreover, the simulation results have been verified experimentally.
参考文献17
-
1D.B. Watson, J Amlaga. T. Densem, Controllable d.c. power supply from wind-driven self-excited induction machines, IEE Proceedings 126 (12) (1979) 1245-1248.
-
2J.B. Patton, D. Curtice, Analysis of utility protection problems associated with small wind turbine interconnections, IEEE Trans. Power Apparatus and Systems 101 (10) (1982) 39-57.
-
3G. Raina, O.P. Malik, Wind energy conversion using a self-excited induction generator, IEEE Trans. Power Apparatus and Systems 102 (12) (1983) 3933-3936.
-
4P. Freere, Electronic load / excitation controller for a self excited squirrel cage generator micro-hydro scheme, in: Fifth International Conference on Electrical Machines and Drives, Publication No. 341, 1990, pp. 266-270.
-
5R.C. Banasal, T.S. Bhatti, D.P. Kothari, A bibliographical survey on induction generators for application of nonconventional energy systems, IEEE Trans. Energy Conversion 18 (3) (2003) 433-439.
-
6R.C. Banasal, T.S. Bhatti, D.P. Kothari, Induction generator for isolated hybrid power system applications: a review, J. Inst. Eng. 83 (2003) 262-269.
-
7N. Elsonbaty, P.G. Holmes, M. Salama, N.P. A Smith, A.A. Williams, VSCF induction generation in stand-alone micro-hydro generating systems, in: International Conference on Renewable Energy-Clean Power 2001, Conference Publication No. 385, 1993, pp. 89-94.
-
8E.D. Basset, F.M. Potter, Capacitive excitation of induction generators, AIEE Trans. 54 (1935) 540-545.
-
9S.S. Murthy, O.P. Malik, A.K. Tandon, Analysis of self excited induction generators, IEE Proceedings 129 (6) (1982) 260-265.
-
10N.H. Malik, A.H. AI-Bahrani, Influence of the terminal capacitor on the performance characteristics of a self excited induction generator, IEE Proceedings 137 (2) (1990) 168-173.
-
1汤蕴璆,梁艳萍.感应电机不对称短路的瞬态[J].电机与控制学报,2000,4(3):129-134. 被引量:2
-
2R.NOROOZIAN,M.ABEDI,G.B.GHAREHPETIAN,S.H.HOSSEINI.A novel control strategy for load converter of DC isolated distribution system under unbalanced loading conditions[J].Journal of Zhejiang University-Science A(Applied Physics & Engineering),2009,10(6):890-899. 被引量:1
-
3张一兵.2005年铁路货车超偏载联网监控工作通报[J].铁道技术监督,2006,34(3):40-41.
-
4王成元,周美文,夏加宽.电流矢量控制异步电机的动态转矩特性[J].沈阳工业大学学报,1992,14(2):6-12.
-
5郝全睿,徐政,黄莹,黎小林.用于高频干扰计算的HVDC换流变压器模型[J].电工技术学报,2008,23(8):47-52. 被引量:6
-
6李春敏,张晓冬,王鹤晓.基于模糊控制的超级电容储能研究[J].电子设计工程,2016,24(4):131-133. 被引量:7
-
7李林.两种变压器绕组等值电容模型的联系[J].四川电力技术,2014,37(6):29-31.
-
8张逸成,朱建新.基于超级电容模型的参数辨识及其仿真研究[J].机电一体化,2010,16(12):13-16. 被引量:9
-
9Rajesh Kumar Thakur,Vivek Agarwal,Paluri S. V. Nataraj.A Reliable and Accurate Calculation of Excitation Capacitance Value for an Induction Generator Based on Interval Computation Technique[J].International Journal of Automation and computing,2011,8(4):429-436.
-
10彭程,潘再平.风力发电系统中PWM整流器脉宽调制方法的研究[J].机电工程,2013,30(8):993-996. 被引量:1