期刊文献+

机械通气中呼吸机湿化罐液体更换时间的探讨 被引量:4

Study on the replace time of breathing machine humidification pot liquid in mechanical ventilation
下载PDF
导出
摘要 目的:探讨机械通气中呼吸机湿化罐液体的更换时间。方法:将33例机械通气患者随机分为观察组和对照组,观察组采用7d更换呼吸机湿化罐液体,对照组采用每天更换呼吸机湿化罐液体,分别每天对2组的湿化罐液体采样进行细菌培养。结果:观察组采集样本119例,有细菌生长3例(2.5%);对照组采集样本112例,有细菌生长15例(13.4%)。结论:呼吸机湿化液频繁更换可能造成细菌污染,7d更换湿化液的细菌污染率明显低于每天更换湿化液的细菌污染率。 Objective:To study on the best replacement time of breathing humidification pot liquid in mechanical ventilation.Methods:33 mechanical ventilation patients were randomly divided into observation group and control group,in the observation group the humidification pot liquid were replaced 7 days,while in a control group were replaced every day,all liquid samples were cultured for bacteria.Results:119 samples collected in observation group have 3 cases with positive bacterial growth(2.5%),while 112 samples collected in control group have 15 cases with positive bacterial growth(13.4%).Conclusion:Replace humidification pot liquid of breathing machine everyday may cause bacterial pollution more easily than they were replaced in 7 days interval.
作者 刘雨村 丁敏
出处 《重庆医科大学学报》 CAS CSCD 北大核心 2010年第5期790-792,共3页 Journal of Chongqing Medical University
关键词 呼吸机湿化液 细菌污染 更换频率 Breathing machine humidification liquid Bacterial pollution Replacement frequency