摘要 在分析砌体局部均匀受压机理的基础上,对现行砌体结构设计规范(GB50003)关于多孔砖砌体局部均匀受压强度计算中存在的不足进行了讨论,考虑多孔砖截面特点,建议了局部均匀受压强度提高系数计算公式。结果表明,多孔砖砌体局部受压强度提高的主要原因是力的扩散作用,理论计算结果与试验结果吻合较好,且优于现行规范公式。 Based on the analysis of failure mechanism of brick masonry under local uniform compression,the shortcomings of the formula about the calculation of increased coefficient of the masonry strength in Chinese code(GB50003)are discussed.For the fired perforated brick masonry under local uniform compression,the reason of strength increase is mainly the influence of force diffusion.An evaluation formula,which can reflect the influence of force diffusion on the strength,is suggested.It shows that the results of evaluation have a good agreement with the experiments'and are better than the code's.
出处 《四川建筑科学研究》 北大核心 2010年第3期48-50,共3页 Sichuan Building Science
基金 河南省教育厅自然科学基金(2009B560011) 郑州大学青年骨干教师基金(511051000)
关键词 多孔砖砌体 局部均匀受压 强度 计算方法 perforated brick masonry local uniform compression strength calculation method
  • 相关文献

参考文献5

二级参考文献14

  • 1杨卫忠.梁端砌体局部受压承载力计算[J].结构工程师,2004,20(4):42-47. 被引量:1
  • 2GB50003-2001.砌体结构设计规范[S].[S].,..
  • 3GBJ3--88.砌体结构设计规范[S].[S].,..
  • 4唐岱新 钱义良 施楚贤.砌体结构局部受压试验及计算方法[A].钱义良,施楚贤.砌体结构研究论文集[C].长沙:湖南大学出版社,1989.163-192.
  • 5.砌体结构设计规范(GB50003-2001)[S].北京:中国建筑工业出版社,2002..
  • 6唐岱新.砌体结构局部受压试验及计算方法,砌体结构研究论文集[M].长沙:湖南大学出版社,1989.
  • 7砌体基本力学性能试验方法标准(GBJ129--90)[S].北京:中国建筑工业出版社,1994.
  • 8多孔砖砌体结构技术规范(JGJ137--2001)[S].北京:中国建筑工业出版社,2001.
  • 9砌体结构设计规范(GBJ3--88)[S].北京:中国建筑工业出版社,1989.
  • 10烧结多孔砖(GBJ13544-2000)[S].北京:中国建筑工业出版社,2000.

共引文献63

同被引文献6

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部