期刊文献+

自动验潮仪数据消波浅析

Analysis on Eliminating Wave by Data of the Auto Tidal Meter
下载PDF
导出
摘要 自动验潮仪对工作环境的要求与传统的瓦尔代式验潮仪完全一样,故新建验潮井必须恪守规范的技术要求,才能使其随潮性和消波性这对矛盾达到对立统一。如果井内不设消波器,进水孔总截面积与井筒截面积之比太大,必然会导致消波性太差。完全依靠自动验潮仪的所谓"数据消波功能"消除井内波动对资料质量的影响是不可能的。 To make it be able to follow tide and to eliminate wave, a new tide gauge well must be built based on the technical requirement of the standard specification because the working environmental requirement for auto tidal meter is the exactly same as that of the traditional WALDI's-instrument of examining tide. If there is no wave eliminator in the well and the area rate of its inlet hole to the well itself is too big, the ability to eliminate the wave should be very poor. It is impossible to remove the impact on the data quality from its inner wave only using the function "eliminates wave by data" of the auto tidal meter.
出处 《海洋技术》 北大核心 2010年第2期36-38,共3页 Ocean Technology
基金 国家海洋局"908"专项<中国海岛志>资助项目(908-ZC-Ⅱ-01)
关键词 验潮井 规范 自动验潮仪 数据消波 tide gauge well standard specification auto tidal meter eliminating wave by data
  • 相关文献

参考文献4

  • 1国家技术监督局1994-10一01实施.海滨观测规范[S].北京:中国标准出版社,3(8.2),8.3),68(R2).
  • 2山东海洋学院海洋热学教研室.海洋学.1982,154-155,158-163,179-181.
  • 3广东省海岸带和海涂资源综合调查报告[R].北京:海洋出版社,1987,139-140.
  • 4黄国镇等.广东海平面变化及其影响与对策[M].广州:广东科技出版社,2000,43,82.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部