期刊文献+

高压加热器泄漏原因分析及对策 被引量:12

The reason of leakage of high pressure heater and countermeasures
下载PDF
导出
摘要 四川华电攀枝花三维发电有限责任公司2×150 MW汽轮机组2005年投入商业运行以来,#2高压加热器在运行中频繁泄漏,截至2007年8月,#11、#12机组堵管率分别达8%和9%,严重影响机组的安全性和经济性。根据#2高压加热器制造、安装、调试、实际运行情况,对#2高压加热器泄漏的原因进行了分析,提出了相应的解决措施。通过有效的治理,使#11、#12机组高压加热器的投入率由先前的79.62%和81.98%提高到现在的99.32%和98.43%,提高了机组运行的安全性和经济性。 The two 150MW steam turbine units of Sichuan Huadian Panzhihua Sanwei Power Generation Corporation Limited were put in operation at 2005.Since then,the leakage fault of high pressure heater No.2 often occurred in operation.Up to the August 2007,the blind tube rate of No.11 and No.12 units reached 8% and 9% respectively,and this influenced on the safety and economical efficiency of the units badly.According to the fabrication,erection,debugging and actual operation of No.2 high pressure heater,the reason of leakage of No.2 high pressure heater was analyzed,and relevant solving measures were proposed.After effective rectification,the operation rate of No.11 and No.12 high pressure heaters were raised from previous 79.62% and 81.98% to present 99.32% and 98.43%,the safety and economical efficiency of the unit operation were raised.
作者 陈涛 魏胜娈
出处 《华电技术》 CAS 2010年第6期47-49,共3页 HUADIAN TECHNOLOGY
关键词 150MW汽轮机组 高压加热器 泄漏 投入率 150MW steam turbine unit high pressure heater leakage operation rate
  • 相关文献

参考文献1

  • 1赵永民.汽轮机设备及运行[M].北京:水利电力出版社,1982.

共引文献3

同被引文献44

引证文献12

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部