期刊文献+

丁二烯橡胶凝胶含量测量不确定度的评定

Evaluation of gel content uncertainty of a measurement of butadiene rubber
下载PDF
导出
摘要 利用生胶碎颗粒在甲苯溶液中溶解一定时间后,留在一定孔径过滤器上的不溶物即为凝胶,通过计算来测定丁二烯橡胶的凝胶含量,依据JJF 1059-1999对丁二烯橡胶(BR)9000凝胶含量测试过程中的测量不确定度分量进行了分析和评定。该测定过程中所产生的不确定度主要由测定重复性的不确定度所决定。丁二烯橡胶(BR)9000凝胶含量测定结果的扩展不确定度为0.05%。 Using raw rubber clips dissolve toluene established time,which preserved above formulated pore filter is gel.By means of calculate to determine gel content of butadiene rubber(BR)9000.According to JJF 1059-1999 to analysis and judgement of measured uncertainty to measured procedure of gel content of butadiene.The uncertainty of a measurement in measured precodure is major judged by measured uncertainty of measure repeatability.The expanded uncertainty of butadiene rubber(BR)9000 gel content is 0.05%.
出处 《石油化工应用》 CAS 2010年第6期74-76,共3页 Petrochemical Industry Application
关键词 丁二烯橡胶 测量不确定 凝胶含量 butadienen rubber measured uncertainty gel content
  • 相关文献

参考文献3

  • 1李慎安 施昌彦 刘风.JJF1059-1999测量不确定度评定与表示[S].北京:中国计量出版社,1999..
  • 2中国合格评定国家认可委员会.检测和校准实验室能力认可准则(ISO/IEC17025:2005)[S].2006.
  • 3韩萍.SH/T1050-1991合成生胶凝胶含量的测定[S].北京.中国石油化工总公司.1991.