期刊文献+

沙角A电厂300MW机组节能诊断分析 被引量:3

DIAGNOSIS AND ANALYSIS OF ENERGY-SAVING FOR 300 MW UNIT IN SHAJIAO A POWER PLANT
下载PDF
导出
摘要 利用粤电沙角A电厂4号机组的全年运行数据,针对其3个典型负荷段的冬、夏、春秋3个季节的节能潜力进行了全面诊断分析,获得了机组运行参数、热力系统运行方式、热力设备性能等因素偏离运行标准值对机组经济指标的影响大小。以此为依据,提出了机组运行、维护和检修建议,以提高机组运行经济性。 By using the whole-year operating data of unit no.4 in Shajiao A Power Plant,a comprehensive diagnotic analysis of energy-saving potential has been carried out for three typical load sections in three seasons.i.e.winter,summer,spring and autumn,and the influence degree of such factors,namely operating parameters of unit,operating mode of the thermal system,and performance of the thermal equipments etc.,upon the economic indices of unit being obtained.Based on these,recomendations for operation,maintenance,and repair of said unit have been put forward,so as to enhance the economic efficiency of unit in operation.
出处 《热力发电》 CAS 北大核心 2010年第6期5-10,共6页 Thermal Power Generation
基金 国家重点基础研究计划项目(973)(No.2009CB219803)
关键词 300MW机组 热力系统 热经济性 节能 诊断 thermal economic efficiency energy-saving diagnosis 300 MW unit
  • 相关文献

参考文献5

二级参考文献15

  • 1Peter Hartley, Alan Moran. Marginal costs and prices in the electricity industry[J]. www. ipa. org. au/pubs/Morarrwebpapers, 2000,6,.
  • 2Royo J, Zaleta A, Valero A. Thermoeconomic analysis of steam turbines: an approach to marginal cost allocation[J].Proceeding of ASME, 1996, (36) :437-444.
  • 3Valero A, Correas L, Serra L. On-line thermoeconomic diagnosis of thermal power plants[A]. In: Bejan, Mamnt, editors. NATO ASI on thermodynamics and optimization of complex energy system[C]. New York. Kluwer Academic Publisher,1999:117-136,.
  • 4Cheng Wei-liang, Wang Xiu-yan, Wang Jia-xuan. A review of thermoeconomic optimization methodology of energy systems part 11 : a study on application of the methodology of the theory of structure [A]. Editors in Chief: Hua Ben, Guo Zengyuan, Ma Chongfang. Proceedings of the 3^rd international symposium on heat transfer and energy conservation [C].Guangzhou, South China University of Technology Press,2004:1327 - 1333.
  • 5Peter Hartley, Alan Moran. Marginal costs and prices in the electricity industry[E]. www. ipa. org. au/pubs/Moranwebpapers, 2000,6.
  • 6Royo J, Zaleta A, Valero A. Thermoeconomic analysis of steam turbines: an approach to marginal cost allocation [J].Proceeding of ASME, 1996, (36):437-444.
  • 7Valero A, Correas L, Serra L. On-line thermoeconomic diagnosis of thermal power plants [A]. In: Bejan, Mamnt, editors. NATO ASI on thermodynamics and optimization of complex energy system[C]. New York: Kluwer Academic Publisher,1999: 117~136.
  • 8Cheng Wei-liang, Wang Xiu-yan, Wang Jia-xuan. A review of thermoeconomic optimization methodology of energy systems part Ⅱ: a study on application of the methodology of the theory of structure [A]. Editors in Chief: Hua Ben, Guo Zengyuan, Ma Chongfang. P
  • 9高海波,李忠满.电价应以边际成本为基础来确定[J].东北电力技术,1997,18(5):59-62. 被引量:6
  • 10王运民.电厂凝汽器冷却水最佳供水方式的确定[J].节能,1998(11):39-40. 被引量:3