期刊文献+

BioWin3动态模拟在城市污水处理厂中的应用 被引量:4

Application Research on BioWin3 Dynamic Simulation to the Operation of Urban Sewage Treatment Plant
下载PDF
导出
摘要 结合招远市某个以百乐克工艺为污水处理工艺的污水处理厂的夏季实际运行情况,用BioWin3软件在计算机上建立仿真模型,并不断调整设定参数,最后通过对模拟水厂出水效果与实际水厂出水效果的比较分析,验证软件模拟的准确程度。 Combined with the actual operation in summer of a sewage treatment plant,where BIOLAK is used as the sewage treatment technology in Zhao Yuan City,the paper established the simulation model with the help of BioWin3 software for this sewage treatment plant. Through continuous adjustment of the parameters,the paper analyzed the different output efficient between simulative water plant and actual water plant,Finally,verified the accuracy of this simulation.
出处 《水资源与水工程学报》 2010年第3期124-126,共3页 Journal of Water Resources and Water Engineering
关键词 BioWin3 活性污泥 百乐克工艺 城市污水处理 BioWin3 activated sludge BIOLAK rurban sewage treatment
  • 相关文献

参考文献12

二级参考文献40

  • 1汪慧贞,曹秀芹.活性污泥模型NO.1及“SSSP程序”在中国污水厂适用性的初步探讨[J].北京建筑工程学院学报,1996,12(3):66-74. 被引量:13
  • 2黄勇,杨铨大,王宝贞,聂梅生.生物处理动力学参数测定研究[J].中国环境科学,1996,16(2):123-127. 被引量:20
  • 3[1]Willi Gujer,et al.Activated sludge model No.3[J].Water Sci Tech,1999,39(1):183-193.
  • 4[2]Sollfrank U,Gujer W.Characterization of domestic was-tewater for mathematical modelling of the activated sludge process[J].Water Sci Tech,1991,23(4/6):1057-1066.
  • 5[1]Kappeler J,Gujer W.Estimation of Kinetic parameters of heterotrophic biomass under aerobic conditions and characterization of wastewater for activated sludge modelling[J].Wat Sci Tech,1992,25(6):125-129.
  • 6[2]Ekama G A,Dold P L,Marais G V R.Procedures for determining influent COD fractions and the maximum specific growth rate of heterotrophs in activated sludge systems[J].Wat Sci Tech,1986,18(8):91-114.
  • 7[3]Wanner,Oskar,Kappeler.Calibration of an activated sludge model based on human expertise and on a mathematical optimization technique a comparison,Water Science and Technology Interactions of Wastewater,Biomass and Reactor Configurations in Biological Treatment Plants Proceedings of the IAWPRC Specialised Seminar[J].1991,25(6):21-23.
  • 8[4]Daniel Mamais,David Jenkins,Paul Pitt.A rapid physical-chemical method for the determination of readily biodegradable soluble COD in municipal wastewater[J].Wat Res,1993,27(1):195-197.
  • 9Schutze M, Butler D, Beck M B. Modelling, simulation and control of urban wastewater systems [M]. London: Springer, 2002.
  • 10Hidromantis. GPS-X Technical Reference [M]. Ontario:Hidromantis, Inc. ,1995.

共引文献110

同被引文献43

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部