摘要
讨论了有源法海底光缆故障探测与定位技术中影响探测范围的因素,确定了接收灵敏度和注入电流与探测距离的关系。研究结果表明:探测范围与注入电流成正比关系,而与接收灵敏度并不是简单的比例关系,在距离较远时近似成对数关系。
This paper deals with the active method for submarine cable fault detection and the location technologies affecting the detection range,and determines the receiver sensitivity and the relationship between the injection current and the detection range.The results show that the detection range is directly proportional to the injection current,but not a simple proportional relationship with receiver sensitivity.At the approximate distance,they form the relationship of logarithm.
出处
《海军工程大学学报》
CAS
北大核心
2010年第3期94-96,共3页
Journal of Naval University of Engineering
关键词
海底光缆
探测范围
有源法
submarine cable
detection range
active method